1 General

1.1 Safety Requirements

This device has been designed and tested in accordance with the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures
and special safety advises given in this manual will be adhered to when using the device.
1.  Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected

to any other climatic conditions than those stated under "Specification".

2.  Device and sensors have to be handled with care (don’t throw, hit, etc.). Protect plugs and sockets from

soiling.

3.  If the device is transported from a cold to a warm environment condensation may cause in a failure of the

function. In such a case make sure the device temperature has adjusted to the ambient temperature
before trying a new start-up.

4.  If device is to be connected to other devices (e.g. via serial interface) the circuitry has to be designed

most carefully. Internal connection in third party devices (e.g. connection GND and earth) may result in
not-permissible voltages impairing or destroying the device or another device connected.

Warning:

  If device is operated with a defective mains power supply (e.g. short circuit from mains voltage

to output voltage) this may result in hazardous voltages at the device (e.g. at sensor socket or interface).

5.  If there is a risk whatsoever involved in running it, the device has to be switched off immediately and to

be marked accordingly to avoid re-starting.
Operator safety may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer period of time.
In case of doubt, please return device to manufacturer for repair or maintenance.

6. 

Warning:

 Do not use these product as safety or emergency stop device, or in any other application

where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material damage.

1.2  Operation And Maintenance Advice

 

Battery Operation

If ´bAt´ is shown in the secondary display the battery has been used up and needs to be replaced. The
device will, however, operate correctly for a certain amount of time. If ´bAt´ is shown in the upper display
the voltage is too low to operate the device; the battery has been completely used up.

Please note: The battery has to be taken out, when storing device above 50°C.
 

We recommend to take out battery if device is not used for a longer period of time!
The real time clock has to be set again after reconnect to the battery.

 

Mains Operation With Power Supply
Warning:

 

When using a power supply please note that operating voltage has to be 10.5 to 12 V DC.

Do not apply overvoltage!! Cheap 12V-power supplies often have excessive no-load voltage.
We, therefore, recommend using regulated voltage power supplies. Trouble-free operation is guaranteed
by our power supply GNG10/3000.
Prior to connecting the power supply to the mains make sure that the operating voltage stated at the
power supply is identical to the mains voltage.

!

 

Connecting/Changing Sensors

Do not use insuitable sensors. Connecting other devices/sensors as specificated may cause a damage to
the instrument and device/sensor! Switch off device before changing the sensor.
Connect sensors before switching on the device, otherwise the sensor may not be detected correctly.
When connecting the sensor the connector may not lock correctly. In such case take the plug not at the
casing but at the buckling protection at the end of the plug. If plug is entered correctly, it will slide in
smoothly. To disconnect sensors do not pull at the cable but at the plug (to open locking mechanism).

Summary of Contents for GMH3111

Page 1: ...UNG 3 2 KONFIGURIEREN DES GER TES 4 2 1 UNIT EINHEITENAUSWAHL 4 2 2 SL ALTI MEERESH HEN KORREKTUR BEI ABSOLUTDRUCK SENSOREN 4 2 3 P OFF ABSCHALTVERZ GERUNG 4 2 4 ADR ADRESSE 4 2 5 OFFS KORREKTUR DES S...

Page 2: ...are Sch den aufweist nicht mehr wie vorgeschrieben arbeitet l ngere Zeit unter ungeeigneten Bedingungen gelagert wurde In Zweifelsf llen das Ger t grunds tzlich an den Hersteller zur Reparatur bzw War...

Page 3: ...f 0 gesetzt Alle Messungen werden von nun an relativ zu dem gesetzten Tara Wert angezeigt Ist die Tara Funktion aktiviert wird der Pfeil Tara angezeigt Zum Deaktivieren die Taste 3 f r 2 sec gedr ckt...

Page 4: ...ivierter Sea Level Funktion wird unten in der Anzeige der Pfeil f r SL angezeigt das Ger t zeigt jetzt den Absolutdruck auf Meeresh he an 2 3 P oFF Abschaltverz gerung Wird f r die Dauer der Abschaltv...

Page 5: ...nleitung GRS3105 Die bertragung ist durch aufwendige Sicherheitsmechanismen gegen bertragungsfehler gesch tzt CRC Folgende Standard Softwarepakete stehen zur Verf gung EBS9M 9 Kanal Software zum Anzei...

Page 6: ...lsensoren Typ GMSD GMXD MRE GMSD GMXD BRE GMSD GMXD BAE F r berdruck Unterdruck bzw Absolutdruckmessungen Sensor in Gewinde G1 4 einschrauben oder Kunststoffschlauch ber passenden Adapter an Drucksens...

Page 7: ...chaltverz gerung keine Taste gedr ckt wurde bzw keine Schnittstellenkommunikation stattfand automatisch ab Die Abschaltverz gerung ist zwischen 1 120min einstellbar oder ganz abschaltbar Anzeige 2 vie...

Page 8: ..._________________________________________________________________________________________________________________ GREISINGER electronic GmbH Hans Sachs Stra e 26 Tel 09402 9383 0 http www greisinger d...

Page 9: ...SPLAY 3 1 5 BASIC OPERATION 3 2 CONFIGURATION 4 2 1 UNIT CHOICE OF THE DISPLAY UNIT 4 2 2 SEA LEVEL CORRECTION FOR ABSOLUTE PRESSURE SENSORS 4 2 3 P OFF AUTO POWER OFF TIME 4 2 4 ADR BASE ADDRESS OF I...

Page 10: ...g as specified the device has been stored under unsuitable conditions for a longer period of time In case of doubt please return device to manufacturer for repair or maintenance 6 Warning Do not use t...

Page 11: ...e function is activated the arrow Tara appears in the display To deactivate tare function press Tara for 2 seconds Please Note Activating deactivating tara clears the max min memories Max Memory Press...

Page 12: ...e sensor s location in meters and leave the configuration by pressing Quit key 6 If the sea level correction is active this will be shown by the functional arrow SL in the display the device now displ...

Page 13: ...3100 To avoid transmission errors there are several security checks implemented e g CRC The following standard software packages are available EBS9M 9 channel software to display the measuring values...

Page 14: ...port A Port B is not used Stainless steel pressure sensors types GMSD GMXD MRE GMSD GMXD BRE GMSD GMXD BAE For measurements of over under or absolute pressure screw sensor to G1 4 pressure terminal or...

Page 15: ...ff if no key is pressed no interface communication takes place for the time of the power off delay The power off delay can be set to values between 1 and 120 min it can be completely deactivated Displ...

Page 16: ..._________________________________________________________________________________________________________ GREISINGER electronic GmbH Hans Sachs Stra e 26 Fon 0049 9402 9383 0 http www greisinger de D...

Reviews: