1. Plug the charger into an AC power
outlet.
2. Insert the battery pack (1) into the
charger (2).
1
2
3
This is a diagnostic charger. The Charger
LED Lights (3) will illuminate in specific
order to comunicate the current battery
status. They are as follows:
STAND BY
CHARGING
FULLY CHARGED
HIGH TEMP.
ERROR
LED 1
RED
RED
BLINKING
GREEN
GREEN
RED
BLINKING
RED
OFF
BLINKING
RED
BLINKING
GREEN
LED 2
OFF
False Defect Note:
When the battery is inserted into the
charger, LED 1 flashes RED and LED 2
flashes Green, remove the battery from
the charger for 1 minute, then reinsert. If
the status LEDs indicate normal, then the
battery pack is good. If the status LED 1
and LED 2 are still blinking, remove the
battery pack and unplug the charger. Wait
1 minute and plug the charger back in and
reinsert the battery pack. If the status LEDs
indicate normal than the battery pack is
good. If the status LED 1 and LED 2 are still
blinking then the battery pack is defective
and needs to be replaced.
CHECKING THE CHARGER
If the battery pack does not charge properly:
Check the current at the power outlet
with another tool. Make sure that the
outlet is not turned off.
Check that the charger contacts have
not been shorted by debris or foreign
material.
If the surrounding air temperature is not
normal room temperature, move the
charger and battery pack to a location
where the temperature is between 7 ˚C
and 40˚C .
CHARGER MOUNTING
1. This charger can be installed hanging
on a wall using two #8 screws (not
supplied).
2. Locate the placement for the charger to
be wall mounted.
3. If fastening to wood studs use 2 wood
screws (not included).
4. Drill two holes on center 145mm apart
ensuring that they are vertically aligned.
5. If fastening to drywall use wall
anchors(not included) and screws to
secure the charger to the wall.
NOTE: If the battery and the charger won’t
be used for a long time, please remove the
battery from the charger and pull out the
AC power plug.