GreenTech RD1830 Series Manual Download Page 11

       

 

 

 

11 

 

Intelligent Radar Level

 

Transmitter

 

Programming Menu

-

RD1830 series

 

 

 

Greentech, Korea 

 

www.greentechkor.com                                                                                                                                                    E-mail: [email protected] 

4. Service:

 

 

The menu of service contains more professional functions, which will be 
used for people who have been trained. Main functions are for false echo 
setting, time variable gain, reset and parameters storage, etc. When LCD 
indicates main menu, press button SELECTION to move the arrow to the 
item of service. LCD indicates as follows: 

BASIC SETTING   
INDICATION   
DIAGNOSE   
SERVICE   
MESSAGE 

 

 

4.1. False echo:

 

When there is a fixed obstacle which is interfering the measurement, you 
can use the function of false echo setting to overcome its interference. 
When LCD indicates the main menu and the menu number is 4, press 
button OK to enter service submenu, LCD indicates as follows: 

FALSE ECHO                                                  4.1 
AMEND IT? 

Press button OK, LCD indicates as follows:   

FALSE ECHO                                                  4.1 
DELETE   
UPDATE 
NEW CREATING   
EDIT 

When you want to update or generate a false ECHO GRAPH, press button 
SELECTION to move the arrow to the needed item, then press button OK 
for confirmation. LCD indicates as follows: 

FALSE ECHO                                                  4.1 
UPDATE/NEW CREATING                     

   

  1.000mm

 

   
LCD asks to input the real echo distance value, after inputting the distance 
value, press button OK for confirmation. LCD indicates waiting, and then 
the instrument enters the state of false echo setting. When it finishes, LCD 
goes back to false echo setting menu. 
Note: the difference between “updating false ECHO GRAPH” and 
“generating false ECHO GRAPH” is that "new false echo curve" is to edit a 
false echo curve; "Update false echo curve" is the original before false 
echo curve based on the edit update. 
 
When you want to delete the false ECHO GRAPH, press button 
SELECTION to move the arrow to the needed item, and then press button 
OK for confirmation. LCD asks waiting. The instrument is processing 
deleting the false echo. After finish, LCD goes back to false echo setting 
menu. 
 
When you want to edit the false ECHO GRAPH, press button SELECTION 
to move the arrow to the needed item and then press button OK for 
confirmation. This function can edit or modify the created false echo to 
adapt the request of special working conditions. After entering the false 
echo edition, LCD indicates as follows: 
(Note: this menu needs professional person for operation):   

FALSE ECHO EDITION 
START POINT   

   

    1.00          AMPLITUDE          1300m(d)   

END POINT                2.00          AMPLITUDE     

 

  1500m(d) 

Two points can be edited a time, the start point and the end point are the 
coordinates for the curve which is needed to be edited. The following 
corresponding value of amplitude is the value to be edited (Note: when 
input or alter the distance coordinates, the corresponding amplitude will 

Summary of Contents for RD1830 Series

Page 1: ...ing digits of edited parameters Indicating the content of the selected parameter Note hereinafter the button is called as KEY SELECTION for easy understanding Amending values of parameters Selecting m...

Page 2: ...ress the OK button to enter programming state display programming main menu Each parameter editor to finish with OK button confirmation otherwise the editor is invalid When done editing press the esc...

Page 3: ...relationship together with low position adjustment When LCD indicates the menu number 1 1 press button SELECTION enter high position adjustment LCD indicates as follows HIGH POSITION ADJUSTMENT 1 2 1...

Page 4: ...u of surface wave LCD indicates as follows SURFACE WAVE 1 3 3 NO Press button OK again and enter the menu of surface wave LCD indicates as follows SURFACE WAVE 1 3 3 YES NO 1 3 3 Solid big stack angle...

Page 5: ...1 3 6 NO Press button OK enter guided wave pipe measurement selecting menu LCD indicates as follows GUIDED WAVE PIPE MEASUREMENT 1 3 6 YES NO Press button SELECTION and select YES and press button OK...

Page 6: ...ter When LCD indicates the menu number 1 5 press button SELECTION to enter output mapping editing menu LCD indicates as follows OUTPUT MAPPING 1 6 LINEARITY Press button OK to enter parameter selectio...

Page 7: ...eters then press button OK for confirmation 1 10 Dead zone Dead zone When there is a fixed obstacle close to the propagator it interferes the measurement when the maximum medium level cannot be up to...

Page 8: ...nstrument indicates measured distance Press button Ok to enter editing mode LCD indicates as follows INDICATING CONTENT 2 1 NO WORKING MAPPING PERCENTAGE DISTANCE CALIBRATED VALUE MEDIUM LEVEL CURRENT...

Page 9: ...er graph indication mode LCD indicates as follows CURVE SELECTION 3 3 ECHO GRAPH When need to select other curves press button OK to enter curve selection menu LCD indicates as follows CURVE SELECTION...

Page 10: ...TANCE Press button SELECTION to select current output mapping mode press button OK for confirming entering the set menu After setting the figures press button OK for confirmation At this time the set...

Page 11: ...s button OK for confirmation LCD indicates waiting and then the instrument enters the state of false echo setting When it finishes LCD goes back to false echo setting menu Note the difference between...

Page 12: ...dium level corresponds to 4mA high medium level corresponds to 20mA 20 4mA means that low medium level corresponds to 20mA high medium level corresponds to 4mA When LCD indicates current output select...

Page 13: ...ction to set the instrument into multiple working mode When LCD indicates language menu number 4 5 press button SELECTION to enter working mode menu LCD indicates as follows HART WORKING MODE 4 6 STAN...

Page 14: ...nally press button OK for confirmation Echo graph indication steps are as follows Method 1 1 Press button OK to enter the programming state LCD indicates program main menu 2 Select submenu press butto...

Page 15: ...15 Intelligent Radar Level Transmitter Programming Menu RD1830 series Greentech Korea www greentechkor com E mail info greentechkor com Attached Diagram...

Page 16: ...16 Intelligent Radar Level Transmitter Programming Menu RD1830 series Greentech Korea www greentechkor com E mail info greentechkor com...

Reviews: