4. Service:
The menu of service contains more professional functions, which will be
used for people who have been trained. Main functions are for false echo
setting, time variable gain, reset and parameters storage, etc. When LCD
indicates main menu, press button SELECTION to move the arrow to the
item of service. LCD indicates as follows:
BASIC SETTING
INDICATION
DIAGNOSE
SERVICE
MESSAGE
4.1. False echo:
When there is a fixed obstacle which is interfering the measurement, you
can use the function of false echo setting to overcome its interference.
When LCD indicates the main menu and the menu number is 4, press
button OK to enter service submenu, LCD indicates as follows:
FALSE ECHO 4.1
AMEND IT?
Press button OK, LCD indicates as follows:
FALSE ECHO 4.1
DELETE
UPDATE
NEW CREATING
EDIT
When you want to update or generate a false ECHO GRAPH, press button
SELECTION to move the arrow to the needed item, then press button OK
for confirmation. LCD indicates as follows:
FALSE ECHO 4.1
UPDATE/NEW CREATING
1.000mm
LCD asks to input the real echo distance value, after inputting the distance
value, press button OK for confirmation. LCD indicates waiting, and then
the instrument enters the state of false echo setting. When it finishes, LCD
goes back to false echo setting menu.
Note: the difference between “updating false ECHO GRAPH” and
“generating false ECHO GRAPH” is that "new false echo curve" is to edit a
false echo curve; "Update false echo curve" is the original before false
echo curve based on the edit update.
When you want to delete the false ECHO GRAPH, press button
SELECTION to move the arrow to the needed item, and then press button
OK for confirmation. LCD asks waiting. The instrument is processing
deleting the false echo. After finish, LCD goes back to false echo setting
menu.
When you want to edit the false ECHO GRAPH, press button SELECTION
to move the arrow to the needed item and then press button OK for
confirmation. This function can edit or modify the created false echo to
adapt the request of special working conditions. After entering the false
echo edition, LCD indicates as follows:
(Note: this menu needs professional person for operation):
FALSE ECHO EDITION
START POINT
1.00 AMPLITUDE 1300m(d)
END POINT 2.00 AMPLITUDE
1500m(d)
Two points can be edited a time, the start point and the end point are the
coordinates for the curve which is needed to be edited. The following
corresponding value of amplitude is the value to be edited (Note: when
input or alter the distance coordinates, the corresponding amplitude will