Tracing Tone Mode

This function provides a means of tracking cables by generating four distinct tones on a 

specific pair or all pairs. The cable can be traced using a tracing probe that is capable of 

detecting tones ranging from 577 Hz to 983 Hz.
The four available tones are as follows:

Tone 1 – Slow Warble (577 Hz and 983 Hz)

• 

Tone 2 – Fast Warble (577 Hz and 983 Hz)

• 

Tone 3 – Stutter (577 Hz and 983 Hz)

• 

Tone 4 – Melody (577 Hz, 983 Hz, 818 Hz, and 923 Hz)

• 
These tones can be sampled using the NETcat Pro’s sounder as shown:

Press to sample

current tone.

w w w . e k t

2

. c o m

Electronics 

Katrangi

 Trading

Summary of Contents for NETcat Pro NC-500

Page 1: ...Katrangi Trading INSTRUCTION MANUAL Read and understand all of the instructions and safety information in this manual before operating or servicing this tool NC 500 NETcat Pro Wiring Tester w w w e k...

Page 2: ...ng purpose Identifies active network device PC HUB on 10 100 1000 BaseT networks displaying device capabilities Indicates presence of a PoE Power over Ethernet source device Verifies wiremaps Detects...

Page 3: ...elow indicates the severity of the hazard The message after the signal word provides information for preventing or avoiding the hazard Immediate hazards which if not avoided WILL result in severe inju...

Page 4: ...nt Failure to understand how to safely operate this tool could result in an accident causing serious injury or death Electric shock hazard Do not connect this unit to AC power circuits Failure to obse...

Page 5: ...humidity Refer to Specifications Use this unit for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe...

Page 6: ...e adjustment button to decrease value 3 Fine adjustment button to increase value 4 Back button 5 Select enter button 6 Low battery icon 5 4 3 2 1 6 The NETcat Pro requires a 9 V alkaline battery When...

Page 7: ...y defaults apply a long push to the button for 5 seconds The reset will then initiate a touch panel calibration and zero offset calibration for all pairs Following this all stored settings i e NVP lan...

Page 8: ...bration Selecting Language allows the user to change the language used within the user interface Selecting Memo Pad allows the user to set a short note or reminder that is saved in memory even when th...

Page 9: ...s intended for testing Please be aware that the multi pair test and coax test have separate NVP values Retest Button Cable NVP Lookup List The Cable NVP library is accessed in the NVP setup screen as...

Page 10: ...tributes of a cable Check for active network device Check for voltages Check for Office Identifiers Check the wiremap Length to short or open A further description of the above tests is detailed in th...

Page 11: ...transmitting data at a rate of 10 Mbps full duplex 100 Base TX This indicates that the device is capable of transmitting data at a rate of 100 Mbps half duplex 100 Base TX FD This indicates that the d...

Page 12: ...s reversed pairs crossed pairs and split pairs Below are examples of detectable faults along with a good wiremap Good wiremap Wiremap with an open at 10 ft on pair 1 2 and shield disconnected Wiremap...

Page 13: ...ts ID number is reported as shown This feature can be used to identify office locations at the distribution panel The resident remote with main unit is ID 1 Office Identifier modules number 2 and abov...

Page 14: ...able of detecting tones ranging from 577 Hz to 983 Hz The four available tones are as follows Tone 1 Slow Warble 577 Hz and 983 Hz Tone 2 Fast Warble 577 Hz and 983 Hz Tone 3 Stutter 577 Hz and 983 Hz...

Page 15: ...mperature 0 C to 50 C 32 F to 122 F Storage Temperature 20 C to 70 C 4 F to 158 F Humidity Up to 95 non condensing Interface Connections RJ45 shielded socket F Type threaded female coaxial NVP Calibra...

Page 16: ...temperature or humidity Refer to Specifications Failure to observe these precautions may result in injury and can damage the unit Battery Replacement 1 Loosen the screw to open the battery compartmen...

Reviews: