h)
Turn off the machine and disconnect the IEC Power cable from
the power supply. Reopen the back cover. Remove the 2 screws
which connect the red wires to the white plastic emergency stop
mechanism, as seen below.
i)
Connect the upper and lower sections of the replacement
emergency stop mechanism by inserting part A into the top of
part C to form part D, the opposite side to the screws. Once these
two parts are secured together they will not be able to be
separated.
A
B
C
D