HPD-T and HPD-HV Hydraulic Sign Post Drivers
Greenlee / A Textron Company
7
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
• Optimal performance occurs at maximum flow.
• Maximum hydraulic fluid temperature must not
exceed 70
°
C (158
°
F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
• Hydraulic flow must not exceed 30 l/min (8 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
• Pressure relief valve setting must not exceed
160 bar (2300 psi) at your tool’s maximum flow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.
FILTER
(10 MICRON)
COOLER
RELIEF
VALVE
160 bar
(2300 psi)
CONTROL
VALVE
FLOW METER
T
P
TOOL
RESERVOIR
PUMP
POWER SOURCE
Hydraulic Schematic
Do not exceed the following hydraulic power
source maximums:
• Hydraulic flow: 30 l/min (8 gpm)
• Pressure relief: 160 bar (2300 psi)
• Back pressure: 15 bar (200 psi)
Failure to observe this warning could result in
severe injury or death.
Specifications
HPD-T and HPD-HV
Type of Hydraulic System
HPD-T ................................................... Open-center
HPD-HV ..................... Open-center or closed-center
Weight
HPD-T
Without Hoses and Adapter ........ 30.6 kg (67.5 lb)
With Hoses and Adapter ................... 34 kg (75 lb)
HPD-HV
Without Hoses, Remote
Control Valve, and Adapter ........ 28.8 kg (63.5 lb)
With Hoses, Remote
Control Valve, and Adapter ........... 32 kg (70.5 lb)
Length x Width x Height
without Adapter .......... 655 mm x 254 mm x 177 mm
(25.8" x 10.0" x 6.7")
Working Pressure .... 105 to 125 bar (1500 to 1800 psi)
Hydraulic Oil
Working Temperature .......... 30 to 70
°
C (86 to 158
°
F)
Accumulator Charging
Pressure (nitrogen) ............................. 50 bar (723 psi)
Blow Frequency
@ 30 l/min (8 gpm) ....................... 25 Hz (1500/min)
Hydraulic Ports at Tool ................................... 1/2" BSP
Hydraulic Ports at Remote Control Valve (HPD-HV)
Pressure .......................... 9/16–18 SAE O-ring boss
Return ................................ 3/4–16 SAE O-ring boss
Hydraulic Power Source