background image

H6400C Reversible Drill

Greenlee / A Textron Company

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

8

Hoses and Fittings

Installation and Maintenance

See publication 99930323, SAE J1273  

(Hose and Hose Assemblies)

Replacement

Refer to a Greenlee Utility catalog or bulletin 99910322 

for a complete selection of hoses and fittings.

Hose Connections

Connecting Hoses

1.  Move the flow lever on the power source to the OFF 

position.

2.  Stop the hydraulic power source.
3.  Connect the tank hose to the tank (or return) port on 

the power source, and then to the tank port on the 

tool.

4.  Connect the pressure hose to the pressure port on 

the tool, and then to the pressure (or supply) port on 

the power source.

Disconnecting Hoses

1.  Move the flow lever on the power source to the OFF 

position.

2.  Stop the hydraulic power source.
3.  Disconnect the pressure hose from the power 

source, and then from the tool.

4.  Disconnect the tank hose from the tool, and then 

from the power source.

5.  Install dust caps over the ports to prevent 

contamination.

Typical Setup

Setup

1.  Stop the hydraulic power source.
2.  Install a drill bit according to the instructions under 

“Installing and Removing Accessories.”

3.  Connect the hydraulic hoses according to the 

instructions under “Hose Connections.”

Summary of Contents for Fairmont H6400C

Page 1: ...eversible Drill 99938596 REV 1 2010 Greenlee Textron Inc 3 10 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register this pr...

Page 2: ...rvice Manual Publication 99918013 All specifications are nominal and may change as design improvements occur Greenlee Textron Inc shall not be liable for damages resulting from misapplication or misus...

Page 3: ...ning could result in severe injury or death Electric shock hazard This tool is not insulated When using this unit near energized elec trical lines Use only certified non conductive hoses and proper pe...

Page 4: ...pecifications and Parts manual Failure to observe this warning could result in severe injury or death Do not disconnect tool hoses or fittings while the power source is running or if the hydraulic flu...

Page 5: ...precautions may result in injury Emergency stop procedure 1 Release the trigger 2 Shut off the hydraulic power source Procedure for connecting or disconnecting hydraulic hoses fittings or components 1...

Page 6: ...lee A Textron Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 6 Identification 1 Trigger 2 Chuck 3 Motor Cap 4 Serial Number 5 Directional Spool 6 Super Spool 7 Handle 8 Tank Port 9 Pre...

Page 7: ...ng the Super Spool Position CLOSED CENTER OPEN CENTER Installing and Removing Accessories Inspect accessories before use Discard accessories that have cracks chips or gouges Failure to observe these w...

Page 8: ...er source and then to the tank port on the tool 4 Connect the pressure hose to the pressure port on the tool and then to the pressure or supply port on the power source Disconnecting Hoses 1 Move the...

Page 9: ...en operating or servicing this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Do not change accessories inspect adjust or clean tool when it...

Page 10: ...e Replace decals when necessary Refer to the Specifications and Parts manual for decal part numbers When disposing of any components hydraulic hoses hydraulic fluid worn parts etc do so in accordance...

Page 11: ...perating properly Remove and clean cartridge Do not disassemble cartridge Install a new factory preset cartridge Air in the hydraulic system Refer to the power source manufac turer s instructions for...

Page 12: ...ax 815 397 1865 Canada 800 435 0786 Fax 800 524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc...

Reviews: