![Greenlee DVC-10 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/greenlee/dvc-10/dvc-10_instruction-manual_2262852010.webp)
10
Frequency Range: 0 to 70 Hz
Test Current: Less than 2 mA
Identifying Energized Conductor: 100 V to 600 V
Frequency Range: 50 to 70 Hz
Indication: Tone
Continuity Test: 0 to 1 M
Ω
Test Current: 5
µ
A (approximate)
Indication: Tone
Diode Test:
Open Circuit Voltage: 1.75 V (approximate)
Test Current: 10
µ
A (approximate)
Note: The fixed probe is positive when checking diodes and continuity.
GFCI Test:
Test Current: 6 mA
±
10% at 120 V
Impedance: 20 K
Ω
nominal
Maximum Test Time: 30 seconds
Recovery Time: 10 minutes
Internal Load: 0.7 W @ 120 V
LED
Min. V
Max. V
12
—
10
48
30
40
120
70
100
208
150
180
240
215
220
277
250
265
347
300
330
480
400
450
600
510
570
Specifications and Accuracy
DVC-6 and DVC-10
Polarity: Automatic
Voltage Range: 12 to 600 Volts (AC or DC)
Internal Basic Load: 0.7 W at 600 V (approximate)
LED Threshold
Summary of Contents for DVC-10
Page 24: ...24...