background image

52066382 REV 1 

© 2013 Greenlee Textron Inc. 

12/13

Read

 and 

understand

 all of the instructions and safety information in 

this manual before operating or servicing this tool.

Lea

 y 

entienda

 todas las instrucciones y la información sobre 

seguridad que aparecen en este manual, antes de manejar estas 

herramientas o darles mantenimiento.

Lire attentivement

 et 

bien comprendre

 toutes les  instructions et 

les informations sur la sécurité de ce manuel avant d’utiliser ou de 

procéder à l’entretien de cet outil.
Vor Bedienung oder Wartung dieses Messgerätes bitte alle 

Anweisungen und Sicherheitsinformationen in diesem Handbuch 

genau 

durchlesen

 und 

beachten

.

Clamp Meters 

 

 

INSTRUCTION MANUAL

MANUAL DE INSTRUCCIONES

MANUEL D’INSTRUCTIONS

BEDIENUNGSANLEITUNG

CM-660
CM-860
CM-960
CMH-600
CMI-600

Español.............23
Français ...........43
Deutsch ............63

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for CM-660

Page 1: ...et bien comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte...

Page 2: ...e Motor Rotation Phase Rotation Peak RMS Capture Capacitance Backlight Zero Mode Other capabilities include Hold Mode to capture the present LCD value Record Minimum Maximum or Average Mode Intelligen...

Page 3: ...Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool could result in an accident causing serious injury or death Electri...

Page 4: ...the contrasting inner layer of insulation is visible Use this unit for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit...

Page 5: ...warnings could result in severe injury or death Electric shock hazard Do not change the measurement function while the test leads are connected to a component or circuit Do not clamp the jaw around a...

Page 6: ...input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or fingers below the dashed line during operation 11 Jaw 12 Center indicator for AmpTip func...

Page 7: ...pTip function is enabled 17 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with filter for accuracy on variable frequency drives 20 AC measurement is selected 21 AC DC m...

Page 8: ...wn on the LCD Note operation when DCA or DC ACA functions are selected offsets any mag netic hysteresis in the jaw If DCA or DC ACA reading before measuring is not zero press the button for 1 second T...

Page 9: ...t categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this warning could result in severe injury or d...

Page 10: ...satility The Greenlee CM 660 CM 860 CM 960 CMH 600 and CMI 600 are true RMS meters The Waveforms and Crest Factors table shows some typical AC signals and their RMS values Waveforms and Crest Factors...

Page 11: ...igh frequency noise on a 50 60 Hz power line Operation Electric shock hazard Contact with live circuits could result in severe injury or death Operating Procedure 1 Refer to the Settings Table Set the...

Page 12: ...00 Only Voltage AC DC COM Current AmpTip DC A N A N A Current AmpTip AC DC A N A N A Current DC A N A N A Current AC DC A N A N A CMH 600 and CMI 600 Only Temperature Temp C or F Current DC A COM Phas...

Page 13: ...lf scale Frequency Function Sensitivity Sine RMS Range 600 V 50 V 5 00 Hz 999 9 Hz 60 0 A AmpTip 40 A 50 00 Hz 400 0 Hz 60 00 A 600 0 A 40 A 50 00 Hz 400 0 Hz DC bias must be less than 50 of the Sine...

Page 14: ...CMH 600 only For CM 960 and CMI 600 only induced error for adjacent current carrying conductors is 0 01 A A AmpTip DC Current CM 960 and CMI 600 only Range Accuracy Range Accuracy 60 00 A 0 00 A to 3...

Page 15: ...A 6 00 A to 60 00 A 1 8 0 05 A 2 0 0 05 A 600 0 A 60 0 A to 600 0 A 1 8 0 5 A 2 0 0 5 A For any measurement when the conductor is not positioned on the center of the jaws add 2 0 to the accuracy for p...

Page 16: ...and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance CM 860 CM 960 CMH 600 and CMI 600 only Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2 0 4 F For film capacitors capacitors with...

Page 17: ...t typical 0 3 mA Open Circuit Voltage typical 3 5 VDC Temperature SELECT Temperature CMH 600 and CMI 600 Range Accuracy 40 0 C 99 9 C 1 0 0 8 C 100 C 400 C 1 0 1 C 40 0 F 211 8 F 1 0 1 5 F 212 F 752 F...

Page 18: ...t OR B Contact precision measurement Non contact EF Detection Typical Voltage Range at 50 Hz to 60 Hz LCD Indication 20 V 10 V 36 V 55 V 23 V 83 V 110 V 59 V 165 V 220 V 124 V 330 V 440 V 250 V 600 V...

Page 19: ...600 Total Accuracy Specified Accuracy 25 digits In an RF field of 3 V m all other modes and models not specified above Total Accuracy Specified Accuracy 20 digits Safety Double insulation per UL IEC...

Page 20: ...III Distribution level Permanently installed machines and the circuits they are hard wired to Some examples include conveyor systems and the main circuit breaker panels of a building s electrical sys...

Page 21: ...t from the circuit Turn the unit OFF 2 Remove the two screws from the battery access door and remove it 3 Replace the batteries making sure to observe the polarity Cleaning and Storage Periodically wi...