CM-1360 • CM-1560 • CMH-1000 • CMI-1000

3

SAFETY ALERT SYMBOL

This symbol is used to call your attention to hazards or unsafe practices which could result in an 
injury or property damage. The signal word, defined below, indicates the severity of the hazard. The 
message after the signal word provides information for preventing or avoiding the hazard.

Immediate hazards which, if not avoided, WILL result in severe injury or death.

Hazards which, if not avoided, COULD result in severe injury or death.

Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage.

Read

 and 

understand

 this material before operating or servicing this  equipment. 

Failure to understand how to safely operate this tool could result in an accident 
causing serious injury or death.

Electric shock hazard:

Contact with live circuits could result in severe injury or death.

Electric shock and fire hazard:

• Do not expose this unit to rain or moisture.

• Do not use the unit if it is wet or damaged.

• Clamp meter, test leads or any other clamp accessory, when used to make a measurement, create 

a System. The System is rated for CAT III 1000 V or CAT IV 600 V when using the test leads or 
accessories provided with the meter. The System CAT and voltage rating is limited by the lowest rated 
component in the System when using test leads or accessories not provided with the meter.

• Inspect the test leads or accessory before use. They must be clean and dry, and the insulation must be 

in good condition. Do not use the test lead if the contrasting inner layer of insulation is visible.

• Use this unit for the manufacturer’s intended purpose only, as described in this manual. Any other use 

can impair the protection provided by the unit.

Failure to observe these warnings could result in severe injury or death.

Electric shock hazard:

• Do not apply more than the rated voltage between any two input terminals, or between any input 

terminal and earth ground.

• Keep hands and fingers below the barriers on the test leads and the clamp meter body.

Failure to observe these warnings could result in severe injury or death.

Important Safety Information

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CM-1360

Page 1: ...n comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle A...

Page 2: ...Mode Zero Mode Intelligent Auto Power Off Automatic ranging Backlit LCD Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings o...

Page 3: ...ged Clamp meter test leads or any other clamp accessory when used to make a measurement create a System The System is rated for CAT III 1000 V or CAT IV 600 V when using the test leads or accessories...

Page 4: ...generates electromagnetic interference can result in unstable or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the me...

Page 5: ...ve common or ground input terminal L1 input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or ngers below the dashed line during operation 11 Jaw...

Page 6: ...7 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with lter for accuracy on variable frequency drives 20 AC measurement is selected 21 AC DC measurement is selected 22 DC...

Page 7: ...rmal mode In zero mode the value on the LCD when the button is pressed becomes the offset As the input value changes the offset is subtracted from the actual value This modi ed value is shown on the L...

Page 8: ...ent categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this warning could result in severe injury or...

Page 9: ...RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor j 1 414 1 1 73 2 The crest factor is the ratio of the peak value to the RMS value it is represented by the Greek letter j AC DC True R...

Page 10: ...e selector to this symbol These icons appear on the display Connect the red lead to Connect the black lead to ALL MODELS Voltage AC V COM Voltage DC V COM Current AmpTip AC A N A N A Current AC A N A...

Page 11: ...400 0 Hz DC bias must be less than 50 of the Sine RMS value Accuracy of Frequency Range Display Range Accuracy xx xx 1 0 0 05 Hz xxx x 1 0 0 5 Hz Voltage Measurement V Hz EF VFD SELECT SELECT VFD AC V...

Page 12: ...for adjacent current carrying conductors is 0 02 A A AmpTip DC Current CM 1560 and CMI 1000 only Range Accuracy Range Accuracy 60 00 A 0 00 A to 3 99 A 1 5 0 15 A 4 00 A to 60 00 A 1 5 0 05 A Induced...

Page 13: ...st factor 1 4 1 at full scale and 2 8 1 at half scale Induced error for adjacent current carrying conductors is 0 05 A A For any measurement when the conductor is not positioned on the center of the j...

Page 14: ...Threshold Between 10 and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2 0 4 F For lm capacitors capacitors with negligible dielect...

Page 15: ...F 1 0 2 F Thermocouples supplied with meter meet standard JIS C 1602 1981 Electric Field A 10 mm 0 4 B SELECT A Non contact OR B Contact precision measurement Non contact EF Detection Typical Voltage...

Page 16: ...digits In an RF eld of 3V m all other modes and models not speci ed above Total Accuracy Speci ed Accuracy 20 digits Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C...

Page 17: ...the main circuit breaker panels of a building s electrical system Measurement Category IV Primary supply level Overhead lines and other cable systems Some examples include cables meters transformers...

Page 18: ...to de veri caci n revise si las bater as est n bajas y es necesario reemplazarlas Garantie vie limit e La soci t Greenlee Textron Inc garantit l acheteur d origine de ces produits que ces derniers ne...

Reviews: