CLM-1000 • CLM-1000E

Important Safety Information

SAFETY ALERT 

SYMBOL

This symbol is used to call your attention to hazards 

or unsafe practices which could result in an injury 

or property damage. The signal word, defined below, 

indicates the severity of the hazard. The message 

after the signal word provides information for pre-

venting or avoiding the hazard.

Immediate hazards which, if not avoided, WILL result 

in severe injury or death.

Hazards which, if not avoided, COULD result in 

severe injury or death.

Hazards or unsafe practices which, if not avoided, 

MAY result in injury or property damage.

Read

 and 

understand

 this material 

before operating or servicing this 

 equipment. Failure to understand how 

to safely operate this tool could result 

in an accident causing serious injury 

or death.

Electric shock hazard:
Contact with live circuits could result 

in severe injury or death.

Electric shock and fire hazard:
• Do not connect this unit to live voltage.
• Do not expose this unit to rain or moisture.
• Do not use the unit if it is wet or damaged.
• Using this unit near equipment that generates 

electromagnetic interference can result in unstable or 

inaccurate readings.

• Inspect the test leads or accessory before use. They 

must be clean and dry, and the insulation must be in 

good condition.

• Use this unit for the manufacturer’s intended purpose 

only, as described in this manual. Any other use can 

impair the protection provided by the unit.

Failure to observe these warnings could result in severe 

injury or death.

Electric shock hazard:
• Do not operate with the case open.
• Before opening the case, remove the test leads from 

the circuit and shut off the unit.

Failure to observe these warnings could result in severe 

injury or death.

Electric shock hazard:
• Do not attempt to repair this unit. It contains no user-

serviceable parts.

• Do not expose the unit to extremes in temperature or 

high humidity. Refer to “Specifications.”

Failure to observe these precautions may result in injury 

and can damage the unit.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for CLM-1000

Page 1: ...toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle Anweisungen u...

Page 2: ...150 185 240 mm2 61 strands 300 400 500 Other capabilities include Automatic temperature compensation Hold Mode to capture the present LCD value Programmable Auto Power Off Automatic ranging Backlight...

Page 3: ...connect this unit to live voltage Do not expose this unit to rain or moisture Do not use the unit if it is wet or damaged Using this unit near equipment that generates electromagnetic interference ca...

Page 4: ...struction manual Warning Risk of electric shock Double insulation Display Icons 1 Low battery indicator 2 User selected switch position 3 Ambient temperature indication 4 Resistance Mode 5 Copper 6 Al...

Page 5: ...e press the HOLD FT M or Cu Al button dH is no longer present on the LCD Auto Power Off APO When enabled the meter will automatically turn OFF after 10 minutes of inactiv ity Inactivity is defined as...

Page 6: ...e odd cable sizes AWG 5 7 9 11 AWG etc CLM 1000 When measuring odd numbered cable sizes set the rotary switch to the next smaller size and multiply the reading by 1 261 For example to measure a 9 AWG...

Page 7: ...Typical Measurements Typical Configuration Calibration Note Make sure that the clips are as close together as possible in order to improve calibration accuracy Calibration Bar www com information itm...

Page 8: ...0 01 kft 100 00 kft 1 5 0 33 kft Length in meters Gauges CLM 1000 Diameter mm2 CLM 1000E Accuracy Range Length Range Accuracy 18 AWG 2 AWG 0 75 35 1000 0 m 5 m 152 4 m 1 0 1 6 m 152 5 m 304 8 m 1 0 2...

Page 9: ...h ISO 9001 2000 for our Quality Management Systems The instrument enclosed has been checked and or cali brated using equipment that is traceable to the National Institute for Standards and Technology...

Reviews: