background image

9

500XP • 500FP

• 

Precision tone 

(500XP only) – red and green LED brightness 

is proportional to 577 Hz and 983 Hz, respectively.

acAlert

®

 Hazardous AC Voltage Warning

The 500XP is not an AC mains power detector.

 This warning 

feature is included only as an aid to safety. This product is not 

intended to be used with AC mains power but should indicate if 

near a hazardous AC voltage.
Available in selected programs of the 500XP only (not 500FP), 

the acAlert

®

 feature is important in the filtered modes where 

there is little hum from the loudspeaker. Should AC at 50 Hz 

or 60 Hz be detected, the probe will rapidly flash the red and 

green LEDs alternately and generate a “booop-(audio)-booop” 

warning sound. Pair tracing tones can be heard during the 

pauses. The warning tone may be overridden for 30 seconds by 

pressing both buttons while the tone is being generated.

Program Options 

The configuration of the 

mains power hum 

and 

precision tone 

filters and acAlert

®

 warning can be adjusted if required. There 

are five settings; 1 is the default that should suit most situa-

tions. The chosen setting is stored in non-volatile memory.

Programming 

Option

Start-up 

Mode

acAlert

®

Power 

Hum 

Reject 

(Hz)

Precision 

Tones 

(Hz)

Comment

1

Hum 

rejection

Off

50 & 

60

577 & 

983

Default

2

Lights only

acAlert

®

 

muted

3

Full

acAlert

®

 

on

4

Basic

Full

60

577

200XP

5

50

983

200XP/50

Operation 

(cont.)

Summary of Contents for 500FP

Page 1: ...0XP and 500FP Tone Probes Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool could result in an accident causing serio...

Page 2: ...Hz the tool will attempt to warn the user Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings on the tool provide information...

Page 3: ...hazards which if not avoided WILL result in severe injury or death Hazards which if not avoided COULD result in severe injury or death Hazards or unsafe practices which if not avoided MAY result in in...

Page 4: ...ip is unable to detect the electric field properly Water may short the headset connections Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not use thi...

Page 5: ...ment for a multimeter test lamp or specially engineered AC mains power detec tor This tool has conductive tips which may cause a short circuit resulting in a dangerous arc flash This unit does not det...

Page 6: ...y with accessories and replacement parts recom mended by Greenlee Do not expose the unit to extreme temperatures or high humidity Refer to Specifications Beware ringing voltage that may be present on...

Page 7: ...nals may be contaminated or corrode if dirt and moisture are present 1 Loosen the two captive screws 2 Observing polarity install a new alkaline 9 V battery Check that the seal is clean and in place a...

Page 8: ...ain a high pitched beep is generated and at minimum gain a low pitched beep is generated Change Filter Mode Quickly tap both and buttons simultaneously to step the unit through the three main operatin...

Page 9: ...ed the probe will rapidly flash the red and green LEDs alternately and generate a booop audio booop warning sound Pair tracing tones can be heard during the pauses The warning tone may be overridden f...

Page 10: ...nfirm exit of programming mode Low Battery Warning If the battery drops below 6 5 V you will hear three tones of falling frequency Typically with an alkaline battery two hours of use remain after the...

Page 11: ...her end of the cable and use the 500XP FP to find the pair with the tone on it Starting with higher gain find the general bundle of the wires that contains the tone Gradually reduce the sensitivity un...

Page 12: ...t be dry for optimum performance and safety 20 C to 50 C maximum humidity 90 no condensation maximum altitude 2000 m Mechanical Protection Designed to survive multiple random orientation drops from 3...

Page 13: ...caused by leaking batteries is not covered by the warranty Cleaning Keep the 500XP FP clear of grease and dust Use a cloth damp ened with isopropyl alcohol solution Avoid aggressive solvents and stron...

Page 14: ...h long term exposure cause hearing damage Complementary Products The 500XP FP can be used with any audio tone generator that produces a signal of a few volts or more in the frequency range 400 Hz to 3...

Page 15: ...rchase Please retain proof of purchase for this period and preferably register your purchase at www greenlee com Do not open the case beyond the battery cover you will invalidate the warranty Water da...

Page 16: ...visite www greenlee com Haga clic en Manuals en la barra en la parte inferior de la pantalla Ingrese 500XP en el campo de b squeda y luego haga clic en SEARCH Este manual aparecer en la lista a contin...

Reviews: