background image

485101 • SP-LP Rev 1 November 2021 

Copyright 2021 © Greenheck Fan Corporation

8

As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications 
without notice.

Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature 
section of the website at Greenheck.com/Resources/Library/Literature.

®

Phone: 715.359.6171 • Fax: 715.355.2399 • Parts: 800.355.5354 • E-mail: [email protected] • Website: www.greenheck.com

Our Commitment

Typical Installation

The ducting from this fan to the outside of the building has a strong effect on the airflow, noise and energy use of 
the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with 
smaller ducts than recommended. Insulation around 
the ducts can reduce energy loss and inhibit mold 
growth. Fans installed with existing ducts may not 
achieve their rated airflow.
Rigid metal duct is recommended for optimal fan 
performance. 
Ensure duct joints and exterior penetrations are 
sealed with caulk or other similar material to create 
an air-tight path and to minimize building heat loss 
and gain and reduce the potential for condensation.
Place/wrap insulation around duct and/or fan to in 
order to minimize possible condensation buildup 
within the duct, as well as minimize building heat 
loss and gain.

*Purchase separately.

INSULATION*

(Place around and over Fan Housing.) 

ROOF CAP*

(with built-in damper)

FAN HOUSING

POWER CABLE*

ROUND DUCT*

ROUND

ELBOWS*

Seal gaps 
around Housing.

Seal duct joints
with tape.

OR

Keep duct 
runs short.

WALL CAP*

 

(with built-in damper)

Replacement Parts List

Part

Part Number Description

485154

Mounting Bracket with two (2) screws  
S4X6

484917

Knockout plate and one (1) screw  
S4X6

485153

Duct Adapter with six (6) screws
S4X30 5pcs   •   S4X12 1pc

485152

Grille with spring clips

485151

Power Pack Assembly – includes motor, 
control board, blower, wheel, and three  
(3) screws.   S4X8 2pcs    •    S4X6 1pc

Summary of Contents for MultiSpec SP-LP0511

Page 1: ...otect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 6 Do not kink the power cord 7 Do not install the unit where ducts are configured as shown in Fig 1 8 Provide m...

Page 2: ...1 8 308 2 1 2 64 10 2 5 265 3 3 4 95 3 1 2 88 13 330 Unit inches mm Supplied Accessories or Grille Qty 1 Long screw ST4X30 Qty 5 SP LP0511 SP LP0511L No Part Name No Part Name 1 Wheel 6 Knockout plat...

Page 3: ...o a value greater than R40 45 45 Do not install fan in this area Fig 2 ATTENTION utiliser pour la ventilation g n rale uniquement Ne pas utiliser pour l aspiration de mati res et vapeurs dangereuses o...

Page 4: ...body See Fig 4 3 Utilize 4 inch circular duct to connect to duct adapter on the fan housing Squeeze the circular duct to fit the adapter and secure it with clamps or ties and seal it with mastic or ap...

Page 5: ...ings into slots as shown and mount grille to fan body See Fig 7 and Fig 8 6 For model SP LP0511L with light a Insert the grille mounting spring on the wiring side into the slot insert the plug into th...

Page 6: ...lation As shown below ATTENTION The duct adapter of product must be installed upward 2 Complete the wiring and duct work please refer to steps 2 and 3 of Joist Mounting Installation page 4 to complete...

Page 7: ...ater over 140 F 60 C Cleaning 1 Remove grille Squeeze mounting spring and pull down carefully See Fig 11 2 Clean grille Do not put into hot water Use non abrasive kitchen detergent wipe dry with clean...

Page 8: ...ed with existing ducts may not achieve their rated airflow Rigid metal duct is recommended for optimal fan performance Ensure duct joints and exterior penetrations are sealed with caulk or other simil...

Reviews: