Model H-G/H-GB Centrifugal Roof Exhaust Fan

Model

Curb

Cap

Damper

Roof

Opening

Number of Screws (per side)

Outside 

Flange

**Approx.  

Weight

With Metal/Steel and Concrete With Wood

H-G 060, 065, 070, 075

17 

(432)

(203)

10

1

2

 

(267)

5

5

26 

(660)

18 

(8 kg)

H-G 080, 085, 090, 095

17 

(432)

10 

(254)

12

1

2

 

(318)

5

5

26 

(660)

26 

(12 kg)

H-G 101, 121

19 

(483)

12 

(305)

14

1

2

 

(368)

5

5

28 

(711)

43 

(20 kg)

H-G 131,141

22 

(559)

16 

(406)

18

1

2

 

(470)

5

5

31 

(787)

59 

(27 kg)

H-G 150

26 

(660)

16 

(406)

18

1

2

 

(470)

5

7

35 

(889)

59 

(27 kg)

H-G 160, 170

30 

(762)

18 

(457)

20

1

2

 

(521)

7

7

39 

(991)

81 

(37 kg)

H-G 180

30 

(762)

18 

(457)

20

1

2

 

(521)

7

7

39 

(991)

118 

(54 kg)

H-GB 071, 081, 091

19 

(483)

12 

(305)

14½ 

(368)

5

5

28 

(711)

58 

(26 kg)

H-GB 101, 101HP

19 

(483)

12 

(305)

14½ 

(368)

5

5

28 

(711)

63 

(29 kg)

H-GB 121

19 

(483)

12 

(305)

14½ 

(368)

5

5

28 

(711)

66 

(30 kg)

H-GB 131

19 

(483)

12 

(305)

14½ 

(368)

5

5

28 

(711)

67 

(30 kg)

H-GB 141, 141HP

22 

(559)

16 

(406)

18½ 

(470)

5

5

31 

(787)

83 

(38 kg)

H-GB 161, 161HP

22 

(559)

16 

(406)

18½ 

(470)

5

5

31 

(787)

89 

(40 kg)

H-GB 180, 180HP

30 

(762)

18 

(457)

20½ 

(521)

7

7

39 

(991)

125 

(57 kg)

H-GB 200, 200HP

30 

(762)

18 

(457)

20½ 

(521)

7

7

39 

(991)

138 

(63 kg)

H-GB 220, 220HP, 240, 240HP

34 

(864)

24 

(610)

26½ 

(673)

7

7

43 

(1092)

158 

(72 kg)

H-GB 260

40 

(1016)

30 

(762)

32½ 

(826)

7

9

49 

(1245)

305 

(138 kg)

H-GB 300, 300HP

40 

(1016)

30 

(762)

32½ 

(826)

7

9

49 

(1245)

320 

(145 kg)

•  All dimensions are in inches (millimeters). *Approximate weight is shown in pounds (kilograms) without the roof curb and is cataloged with the largest Open Drip Proof motor. **May be 

greater depending on the motor.

•  The roof curb should be 1½ inches (38 millimeters) less than the curb cap to allow for roofing and flashing.

Typical Curb Installation

Concrete Deck Anchoring

Metal Building/Steel Deck Anchoring

Wood Deck Anchoring

Fig. 5

Minimum Concrete

Strength of 2000 PSI

Roof Opening

Roof Opening

Center fasteners

 on flange

Outside Flange

Use #12 Wood Screws or equal into 

minimum No. 1/No. 2 Southern Pine 

wood support.

Fasteners one on each corner as 

detailed.

Each side at center of unit. Maximum 

fastener spacing of 6 in. 

(152 mm)

, add 

additional fasteners to satisfy.

Wood Support Member

Nominal 2 x 4, 6, 8

Wood Decking

2 in 

(51 mm)

  

Minimum 

Embedment

5 in. 

(127 mm)

 Mounting Flange

1 in. 

(25 mm)

 Insulation

H-GPF Curb Height

8 to 18 in. 

(203 to 457 mm)

(Optional 24 in. 

(610 mm)

 SD Curb)

Outside of Roof Curb 

1 in. 

(25 mm)

 less than Fan 

Curb Cap

Minimum 12 ga Steel

Roof Truss

Outside Flange

Center fasteners

 on flange

Use #12-14 self-drilling screws or equal. 

Fasteners one on each corner as 

detailed.

Each side at center of unit. Maximum 

fastener spacing of 8 in. 

(203 mm)

, add 

additional fasteners to satisfy.

Corrugated Roof Deck

5 in. 

(127 mm)

 Mounting Flange

1 in. 

(25 mm)

 Insulation

H-GPF Curb Height

8 to 18 in. 

(203 to 457 mm)

(Optional 24 in. 

(610 mm)

 SD Curb)

Outside of Roof Curb 

1 in. 

(25 mm)

 less than 

Fan Curb Cap

Corner Detail  

(All three options)

11/4 in. 

(32 mm)

 

11/4 in.

 

(32 mm)

1 in. 

(25 mm)

 Insulation

Roof Opening

5 in. 

(127 mm)

 Mounting Flange

Outside Flange

Center fasteners 

on flange

Use 

3

8

 in. 

(10 mm)

 expansion anchor 

or equal into concrete.

Fasteners one on each corner as 

detailed.

Each side at center of unit. Maximum 

fastener spacing of 8 in. 

(203 mm)

add additional fasteners to satisfy.

Minimum 13/4 in.  

(44 mm)

 edge distance

2

1

2

 in. 

(64 mm)

Embedment Recommended 

minimum 1

5

8

 in. 

(41 mm)

H-GPF Curb Height

8 to 18 in. 

(203 to 457 mm)

(Optional 24 in. 

(610 mm)

 SD Curb)

Outside of Roof Curb 

1 in. 

(25 mm)

 less than Fan 

Curb Cap

  CONCRETE DECK ANCHORING DETAIL

Summary of Contents for H-G 060

Page 1: ...nt should be checked to make sure it is not exceeding the motor nameplate amps 5 Do not allow the power cable to kink or come in contact with oil grease hot surfaces or chemicals Replace cord immediat...

Page 2: ...e necessary depending upon roofing material thickness The motor amperage and voltage ratings must be checked for compatibility to supply voltage prior to final electrical connection For H G H GB insta...

Page 3: ...of rust occur Immediately remove the original rust preventive coating with petroleum solvent and clean with lint free cloths Polish any remaining rust from surface with crocus cloth or fine emery pape...

Page 4: ...ring leads or check motor wiring for single phase Table 1 Model Fasteners Per Side Total Fasteners H G 060 141 3 12 H G 150 180 5 20 H GB 071 161 3 12 H GB 180 300 5 20 5 Secure fan to curb Fasteners...

Page 5: ...071 161 1 4 6 H GB 180 240 3 8 10 H GB 260 300 1 2 13 Do not force belt s Forcing the belt s will break the cords and cause belt failure Belts Fig 11 Slack Side Deflection Fig 14a Fig 14b 11 Belt ten...

Page 6: ...elt Bearing Maintenance H GB Unit 1 Belts tend to stretch after a period of time They should be checked periodically for wear and tightness When replacing belts use the same type as supplied with the...

Page 7: ...If unit is to be left idle for an extended period remove belts and store in a cool dry place to avoid premature belt failure Recommended Relubrication Frequency in Months NOTE If unusual environment...

Page 8: ...Deck Anchoring Metal Building Steel Deck Anchoring Wood Deck Anchoring Fig 15 Minimum Concrete Strength of 2000 PSI Roof Opening Roof Opening Center fasteners on flange Outside Flange Use 12 Wood Scre...

Page 9: ...uctwork Check proper operation of face and bypass dampers Check filters and access doors FAN DOESN T OPERATE Electrical Supply Check fuses circuit breakers Check for switches off Check for correct sup...

Page 10: ...on Model Volts Hertz Phase Amps Mark Supply hp Exhaust hp Serial Number Motor Voltage Motor Amperage Fan rpm Service Organization Address City State Zip Phone Fax Work Done By Field Start Up Documenta...

Page 11: ...ng service and replacement parts Before taking any corrective action make certain unit is not capable of operation during repairs CAUTION A fan manufactured with an explosion resistant motor does not...

Page 12: ...k will not be responsible for any removal or installation costs As a result of our commitment to continuous improvement Greenheck reserves the right to change specifications without notice Greenheck C...

Reviews: