background image

Issu

e n

o: 

70

55

17

TECHNICAL INFORMATION

R

ated voltage:

110/120V AC

No of Poles:

2

Rated Current:

16 Amps

(4 amps inductive load)

Rated Tripping Current: 30 mA

Frequency:

50/60Hz 

Environmental Protection 

Rating:

IP65

Conforms to:

IEC 61540

INSTALLER

- Please pass instruction manual onto the

owner of the unit

Please keep these instructions 

for future reference

.

WEST  ROAD  .  HARLOW

ESSEX . CM20 2BG . UK

[email protected]

WWW.GREENBROOK.CO.UK

Your PowerBreaker 16A In-line RCD

is guaranteed for 12 months from 

the date of purchase. 

This does not affect your statutory rights. 

GUARANTEE

Note:

The PowerBreaker Safety In-line Portable RCD

has been designed for storage and use

between -5°C and +40°C at an altitude no

greater than 2000m above sea level. Care

must be taken not to subject your

PowerBreaker to abnormal pollution by smoke

chemical or flammable fumes, salt laden

spray, prolonged periods of high humidity,

immersion, repeated dropping, or any other

abnormal conditions.

IMPORTANT

After installing the leads to the terminals apply

RTV over three terminals and any exposed

conductors covering all bare metal and PVC

insulated inner wires (Brown,Blue,

Green/Yellow). Apply RTV silicon rubber

sealant over the INPUT terminals by squeezing

the tube of RTV over the wiring compartment.

The coating thickness should be at least 3mm.

Use the entire contents of the tube then 

discard the empty tube.

Repeat the RTV application using 2nd tube

tube of RTV for the OUTPUT terminals.

Only use supplied and approved RTV

The strain relief cover should be installed

immediately without waiting for the RTV to

cure. The cure time at room temperature is

approximately 24 hours. The PRCD may be

used as soon as the strain relief cover is

secured.

CAUTION: 

RTV irritates eyes, RTV may irritate

nose, throat and respiratory tract. RTV may

cause allergic skin sensitivity. Avoid contact

with RTV. Avoid prolonged breathing of RTV

vapours. Avoid prolonged or repeated skin

contact with RTV, wipe off RTV and if RTV

comes in contact with the eye, flush with

water immediately. During use of RTV

Methanol is released. Keep RTV out of use of

children.

- Perform the following step for both INPUT 

line and OUTPUT load sides of the unit.

Locate the strain relief cover over the two 

screw posts and insert both screws. While 

alternating between the strain relief screws

gradually tighten the strain relief while 

holding the outer jacket of the wire fully 

into the unit until it is held securely.

J62-Y Ins July 19.qxp_J62-T  03/09/2019  14:16  Page 2

Reviews: