background image

 

IMPORTANT SAFETY INSTRUCTIONS (DO’S AND DON’TS): 

BEFORE PROCEEDING FURTHER KINDLY GO THROUGH THE SAFETY INSTRUCTIONS    

1. 

CONNECT TO MAINS SUPPLY & CONNECT THE OUTPUT WIRES TO THE BATTERY AND THEN POWER 
ON THE INPUT SWITCH. INPUT POWER WIRING SHALL BE FOR MINIMUM 16 AMP. 

2. 

 THE BATTERY BANK SHALL BE PROPERLY INTERCONNECTED WITH RATED WIRE & THE TERMINAL 
CONNECTION POINTS SHALL BE CLEAN.  

3. 

BATTERY BANK VOLTAGE SHALL BE WITHIN 8 V TO 82.5 V  

4. 

DO  NOT INSTALL  THIS  CHARGER  ON OR  NEAR  FLAMMABLE        MATERIALS  (PLYWOOD,  CHEMICALS 
AND GASOLINE ETC.). 

5. 

PLACE  THE  CHARGER  ON  ITS  WALL  HANGING  ARRANGEMENT  OR  ON  THE  FOOT  REST.  KEEPING 
UPWARD DIRECTION. DO NOT KEP IT HORIGENTALLY.   

 

TAKE IT TO OUR SERVICE CENTRE IN CASE OF ANY MALFUNCTION AND OR IF ANY SERVICE IS REQUIRED.  
OPENING  BY  UNQUALIFIED  PERSONNEL  CAN  RESULT  ELECTRIC  SHOCK  OR  FIRE  HAZARD.  OPENING  OF 
THE  UNIT  EXCEPT  BY  OTHER  THAN  SIGNOTRON  ENGINEER  WILL  LEAD  TO  CANCELLATION  OF  THE 
GUARANTEE OF THE PRODUCT.

 

 

TROUBLE SHOOTING  

(IF THE CHARGER IS NOT CHARGING THE BATTERY BANK FOLLOW THE LED INDICATIONS TO FIND THE 

ROOT CAUSE AND RECTIFY) 

 

 

 

 

 

 

 

SYMPTOMS 

PROBLEM 

REMEDY 

MAINS ON LED OFF 

1.

 

WIRING PROBLEM OR INPUT 
SWITCH OFF. 

2.

 

LOOSE CONNECTION / NO VOLTAGE 
AT PLUG POINT. 

3.

 

INPUT FUSE BLOWN 

1. 

CHECK WIRING & ON INPUT 
SWITCH 

2. 

CHECK INPUT VOLTAGE AND 
CHECK ALL CONNECTION. 

3. 

CHECK AC FUSE 

 

NO / REV. BATTERY GLOWING 

BATTERY CONNECTION WRONG 

CHECK THE BATTERY BANK VOLTAGE SHALL 
BE > 8 V ALSO CHECK BATTERY BANK 
WIRING 

 

 

 

CHARGING ON 

CHARGING PROCESS IS ON. IN CASE IT  

GETS OFF PLEASE CHECK LCD DISPLAY 

ACT AS PER LCD DISPLAY GUIDANCE 

 

 

 

CHARGER FAULT  LED GLOWING 

  INPUT SUPPLY VOLTAGE OUT OF RANGE  

OR INTERNAL TRIP 

MAKE THE INPUT SWITCH OFF AND ON 
AFTER A DELAY OF FEW SECONDS 

Reviews: