SPECIFICATION

Voltage:   

 

230V AC

Lampless: 

   

 

Epistar 8W LED

Weather Resistance:  

IP44

Electrical Safety:    

BSEN60598 (Relevant clauses)

Angle of Detection:  

120° approx

Max. Detection Range:  

Up to 6 metres approx; depending  

 

 

 

on weather conditions and mounting height  

 

 

 

(see INTRODUCTION on Page 2).

Mounting Height:    

1.4 to 1.9 metres.

Lux up Operation:   

Lux up operation in hours of darkness only.

Time On:  

 

60 secs & 60 seconds from last trigger.

 

Green Lighting Helpline on 01905 610200

TRI-SENSOR™ TECHNOLOGY

Summary of Contents for GL4689LU

Page 1: ...customer has a copy of these instructions SPECIFICATION Voltage 230V AC Lampless Epistar 8W LED Weather Resistance IP44 Electrical Safety BSEN60598 Relevant clauses Angle of Detection 120 approx Max Detection Range Up to 6 metres approx depending on weather conditions and mounting height see INTRODUCTION on Page 2 Mounting Height 1 4 to 1 9 metres Lux up Operation Lux up operation in hours of dark...

Page 2: ... to work at its best the PIR should be crossed not approached head on The examples below illustrate this The sensor is controlled by a built in photocell so that it operates only between dusk and dawn Once the sensor has turned on the light it will stay on for approximately 60 seconds NOTE When the lantern is positioned directly facing a person walking straight towards it the detection range can b...

Page 3: ...MUST BE EARTHED UNDER NO CIRCUMSTANCES SHOULD THIS METAL FITTING BE WIRED TO AN UNEARTHED CIRCUIT CONTACT A QUALIFIED ELECTRICIAN TO INSTALL A SUITABLE EARTH FACILITY IF YOU ARE IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN Please note For new installations check for any electrical cables or pipe work gas water in the vicinity of the intended mounting point for the product before proceeding with th...

Page 4: ... using the following colour code for the wiring FIGURE 3 Connect the wire coloured Brown or Red Live to the corresponding Brown wire in the terminal block or the terminal marked L Connect the wire coloured Green Yellow or Green Earth to the corresponding Green Yellow wire in the terminal block or the terminal marked E or Connect the wire coloured Blue or Black Neutral to the corresponding Blue wir...

Page 5: ...erride switch InitialPowerUpCycle FIGURE 4 1 3 On the initial power up your lantern will go into one complete cycle that is full light for 45 seconds followed by a slow dim down and it will then switch off in day time This power up cycle will happen regardless the light level of the environment After installing your P Lux3 LED lantern simply walk past your lantern and look for the blue LED Motion ...

Page 6: ...e Cover the photo cell with a dark cloth then test Move the unit to a different height and or change the angle of approach see INTRODUCTION Move lantern away from other lighting Reposition lantern Call the help line Reposition lantern Temporary situation If annoying switch lantern off Please note that this equipment and its components have NO user serviceable parts GREEN LIGHTING HELPLINE TEL 0190...