5.3.4 Remote connection
The WMS allows remote support via an internet connection (see Figure
5.3). The internet connection must be established in accordance with the
electrical documentation.
This connection allows Green Instruments technicians and programmers
to remotely monitor, diagnose, control, and program the WMS if needed.
Remote access to the device is achieved by means of a private, point-to-
point connection. Access to this connection is strictly controlled and all data
sent and received on the connection are encrypted.
Figure 5.3: Remote connection
The following outbound rules must be granted to the remote connection:
■
TLS through Web proxy (TLS to remote IP address and port of Web proxy)
■
HTTPS (HTTP over TLS) to remote IP address of GateManager,
remote port 443
■
TLS over HTTP to remote IP address of GateManager, remote port 80
To enable this function, contact Green Instruments for further information.