background image

__________________________________________________________________________________ 

Green-GO Dante Interface X   – Quick Start Guide

 

Configuration cloning

 

All devices on the local Green-GO network need to have the same configuration to be able to 
communicate with each other. 

Clone Config  

à

 

Clone a configuration file from the network

 

 

 

Configuration File A 

à

 

Load configuration file A 

 

 

Configuration File B 

à

 

Load configuration file B 

 

 

etc. 

 

 

Factory Default     

à

 

Load the factory default configuration file 

Set up Network  

In the Network menu you can set up the Network setting of the Internal Green-GO network. 

Dynamic 

à

 

Select the connection mode. 

 

ON 

à

 

Use a dynamic IP. If an DHCP server is on the network this will supply an  

 

 

IP address to the device. If there is no DHCP server the device will self-assign 

 

 

a Link local IP. 

 

OFF 

à

 

Use a static IP 

 

 

IP address   

à

 

Set the IP address to be used 

 

 

Netmask   

à

 

Set the netmask to be used 

 

 

Gateway   

à

 

Set the gateway to be used 

Save   

à

 

Save the current network setup 

Cancel 

à

 

Discard current network changes 

 

Device options 

Device specific settings can be modified in this menu. 

Device Options

 

Exit   

à

Backlight 

à

 Set the time out of the display. Always on, or a range from 10 seconds 

through 4 hours.

 

Display 

à

 

Set the Intensity of the display to dark or bright. 

 

 

Generic device settings

 

Summary of Contents for Dante Interface X

Page 1: ...Dante Interface X Quick Start Guide...

Page 2: ...ccur during analog to digital and contrary conversion This is ideal for purposes like program audio and announcements or complete user based engines with 32 channels program audio announcement and eme...

Page 3: ...ons are described in detail below To Set up a Dante connection first select the mode to use Select a port and scroll down to Set User Mode Dante connection x Set User Mode Line in out Set up this port...

Page 4: ...off the Max Gain becomes gain MaxGain Set the maximum gain of the input signal range is from 12 to 28 dB Threshold Set the gate function for this input The threshold is the level required for the inp...

Page 5: ...up Select a group label User Select a user label Clear Clear the label set Talk For Future Use Disable talk is disabled for this channel Momentary talk is enabled as long as a corresponding trigger is...

Page 6: ...am audio whenever one of the Channels including announcement and emergency is active Range is from 0 dB to 24 dB and MUTE option Audio In Out Output Set the output level of the Dante Output Range is M...

Page 7: ...eply to a incoming call Auto answer the port automatically replies with a Hold to a call Ignore the port ignores incoming calls Set up the connection type of a Dante connection Connection Set up the c...

Page 8: ...the Network setting of the Internal Green GO network Dynamic Select the connection mode ON Use a dynamic IP If an DHCP server is on the network this will supply an IP address to the device If there i...

Page 9: ...of the Dante Interface X SN xxx Serial number of the Dante Interface X Dante interface 4a61 Firmware information Dante interface 4a61 Firmware version Nov 16 2018 Date of firmware build 09 32 09 Time...

Page 10: ...s instructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or...

Page 11: ...Dante Interface X Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive...

Reviews: