Green-Go Dante Interface X Quick Start Manual Download Page 6

__________________________________________________________________________________ 

Green-GO Dante Interface X   – Quick Start Guide

 

Program Audio 

à

Set up the Program Audio channel for this Dante connection.

 

 

Mode  

à

 

Select Normal or Local IFB. Normal mode will allow you to select. 

  

 

 

one of the available Groups in the Green-GO network on the Program 

 

 

 

audio channel. Local IFB will send the input of the Dante connection to 

 

 

 

the Program audio of this port. This audio stream is not Available on  

  

 

 

the Green-GO network.

 

 

Src   

à

 

Select the Group as program audio source. Not available in Local IFB

 

 

Vol

   

à

 

Set the volume of the program audio. Range is Mute, -36 dB  

 

 

 

through 12 dB 

 

 

Dim  

à

 This will Attenuate the program audio whenever one of the  

 

 

 

Channels including announcement and emergency is active. Range is 

 

 

 

from 0 dB to -24 dB and MUTE option.

 

Audio In/Out 

 

Output  

à

Set the output level of the Dante Output. Range is MUTE, -42 to 6 

 

 

dB. 

LoopBack  

à

 

Set the ratio of audio feed back from the input back to the output. 

 

 

range is 0 to -39 dB or turned off. 

AutoGain  

à

Set the dynamic amplification to avoid distortion. Available settings 

 

 

are Slow/Med/Fast/Off. If AutoGain is turned off the Max  Gain  

 

 

becomes gain. 

MaxGain  

à

 

Set the maximum gain of the input signal - range is from -12 to 28 

 

 

dB. 

Threshold  

à

Set the gate function for this input. the threshold is the level  

 

 

required for the input signal to be transmitted – editable range is 

 

 

from -45 to -20dB or turned Off. 

Hold    

à

Set up the Gate hold time for this input. Options:  

 

 

 

Fast/Med/Long/XLong 

In  

 

à

 

Set up the input source for this input. Line In or a 125 Hz to 4 kHz 

 

 

test tone 

 

 

Summary of Contents for Dante Interface X

Page 1: ...Dante Interface X Quick Start Guide...

Page 2: ...ccur during analog to digital and contrary conversion This is ideal for purposes like program audio and announcements or complete user based engines with 32 channels program audio announcement and eme...

Page 3: ...ons are described in detail below To Set up a Dante connection first select the mode to use Select a port and scroll down to Set User Mode Dante connection x Set User Mode Line in out Set up this port...

Page 4: ...off the Max Gain becomes gain MaxGain Set the maximum gain of the input signal range is from 12 to 28 dB Threshold Set the gate function for this input The threshold is the level required for the inp...

Page 5: ...up Select a group label User Select a user label Clear Clear the label set Talk For Future Use Disable talk is disabled for this channel Momentary talk is enabled as long as a corresponding trigger is...

Page 6: ...am audio whenever one of the Channels including announcement and emergency is active Range is from 0 dB to 24 dB and MUTE option Audio In Out Output Set the output level of the Dante Output Range is M...

Page 7: ...eply to a incoming call Auto answer the port automatically replies with a Hold to a call Ignore the port ignores incoming calls Set up the connection type of a Dante connection Connection Set up the c...

Page 8: ...the Network setting of the Internal Green GO network Dynamic Select the connection mode ON Use a dynamic IP If an DHCP server is on the network this will supply an IP address to the device If there i...

Page 9: ...of the Dante Interface X SN xxx Serial number of the Dante Interface X Dante interface 4a61 Firmware information Dante interface 4a61 Firmware version Nov 16 2018 Date of firmware build 09 32 09 Time...

Page 10: ...s instructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or...

Page 11: ...Dante Interface X Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive...

Reviews: