GROUP 3: BATTERY DISCONNECTED
30 The battery has been disconnected before the begin of the charge, while the charger was waiting for the programmed
Start Time window.
31 The battery has been disconnected during the first part of the charge, before to reach the gassing voltage.
32 Successful Opportunity charging cycle.
The battery reached the gassing point, the charger entered in stand-by mode waiting for the Full Charge/Overcharge
time window, and at that point the battery has been disconnected.
33 The battery has been disconnected during the finishing charge, while it was cooling between two charging pulses.
34 The battery has been disconnected during the finishing charge, while it was receiving a charging pulse.
36 Charge never started.
The battery has been disconnected while the charger was trying to establish a wireless connection with the Battery
Identification Module (WBM).
37 Charge never started.
The battery has been disconnected while the charger was communicating with the Battery Identification Module (WBM).
38 Desulphation cycle NOT completed.
The battery has been immediately disconnected, at the beginning of the Desulphation cycle
39 Desulphation cycle NOT completed.
The battery has been immediately disconnected, before to complete the programming of theDesulphation cycle.
40 Desulphation cycle NOT completed.
The battery has been disconnected while the Desulphation cycle was in progress.
GROUP 4: EMERGENCY STOP
60 Emergency Stop!
Maximum voltage limit exceeded during first part of the charge, before to reach the gassing voltage.
61 Emergency Stop!
Maximum voltage exceeded during the finishing charge.
62 Emergency Stop!
Maximum voltage exceeded during the equalize cycle.
63 Emergency Stop!
Gassing voltage not reached within the predetermined time limit.
64 Charge never started.
Battery voltage was too LOW
65 Charge never started.
Battery voltage was too HIGH
66 Emergency Stop!
Maximum Current Limit Exceeded.