background image

Installation Instructions

For the  Air Curtain

Model No: AC3000N

IMPORTANT

This product should be installed by a 

competent  person and in accordance with 

the current IET Wiring Regulations, and 

Building Regulations. If in doubt, 

consult a qualified electrician. 

• This product is not intended to be used by

children and persons with sensory, physical 

and/or mental impairments that would 

prevent them from using it safely.

• Extreme caution is necessary where children 

or persons with reduced physical, sensory or 

mental capabilities may come into contact 

with the heater when in use.

The Air Curtain unit is designed for easy

installation and can be wall or ceiling mounted.

The unit has a fan and two heat settings and its

angle can be adjusted. This unit is ideal for

providing a heated air curtain if mounted over

doorways and reduces draughts and the 

discomfort of cold air when doors are opened. 

2. Loosen, but do not remove the retaining

bolt using a spanner as shown in 

diagram (2) and remove the bracket 

- see diagram (5).

3. Make fixing holes in wall or ceiling using 

the wall bracket as a template and 

secure bracket using the fixings supplied.

If the fixings supplied are not suitable for 

your installation, use appropriate 

alternative fixings - see diagram (3). 

Note:

the bracket must be fixed to a 

solid point e.g. brick, concrete, stud or 

joist.

4. Hang the Air Curtain on the bracket, 

ensure that the bracket is located 

between the bolt and the serrated 

washer and that the bolts are at the end

of the slots in the bracket see diagram 

(2).

5. Adjust the Air Curtain to the required 

angle  and tighten the bolts using a 

spanner. Take care not to overtighten.

6. Re-fit the front panel.

7. Connect Air Curtain to mains supply 

using a switched 13A fused spur to the

corresponding symbols.

Live 

- Brown or Red

Neutral 

- Blue or Black

Earth 

- Green and Yellow

Switch off mains supply and remove the 

appropriate circuit fuse or MCB before 

commencing installation  or maintenance.

• In order to avoid overheating do not cover 

or obstruct grilles or air intake openings 

when in use.

• The Air curtain must not be located 

immediately adjacent to or under/against 

an electrical socket outlet.

• Do not operate the Air curtain with a 

damaged cord/plug or if heater 

malfunctions. If the supply cord is damaged 

it must be replaced by a qualified 

electrician

• Before making any fixing holes make sure 

there are no pipes or cables below the         

surface.

• Make sure the Air curtain is anchored to a 

solid surface which can take the weight of 

the Air curtain.

• This Air curtain is for indoor use only.

• This Air curtain must be connected to earth.

• Position the Air curtain ensuring that hot air

cannot blow directly onto flammable 

surfaces.

• This Air curtain is not equipped with a 

device to control the room temperature. Do

not use this Air curtain in small rooms when 

they are occupied by persons not capable 

of leaving the room on their own, unless 

constant supervision is provided.

• If the unit overheats, thermal switches will 

cut the power and will restore the power 

when the unit has cooled down. However, if

the unit overheats severly, thermal fuses will 

isolate the power, these fuses will not reset 

and cannot be replaced by the user.

INTRODUCTION

INSTALLATION

WARNING

1. Remove the four screws from the front 

panel and remove it see diagram (1).

Dia:1

Dia:2

Dia:3

Dia:4

8. Restore power and switch on the main 

switch (red illuminated). Heating levels 

are controlled by two switches (4) for 

half and full load see diagram 5.

AC3000N Ins Feb 19.qxp_Layout 1  01/02/2021  16:51  Page 1