background image

Installation, Operating, Maintenance
and After Sales Manual. 

Product Serial Number: 

Please leave this manual with the end user.

Part Number: 1371052
Issue 2

heating

through

innovation.

HI-LINE RC & HI-LINE RC Heater/Cooler
Models: 7-4, 10-6, 15-10, 20-14

01.01.2012  ISSUE 2

Tested to UL & CSA Standards

24392 HiLine manual_Layout 1  22/12/2011  11:07  Page 2

Summary of Contents for 10-6

Page 1: ...er Sales Manual Product Serial Number Please leave this manual with the end user Part Number 1371052 Issue 2 heatingthroughinnovation HI LINE RC HI LINE RC Heater Cooler Models 7 4 10 6 15 10 20 14 01 01 2012 ISSUE 2 Tested to UL CSA Standards ...

Page 2: ...it Selection Sizing 03 4 0 Location 03 5 0 Preparation 04 6 0 Fixing 04 7 0 Water Connections 05 8 0 Electrical Connection 06 9 0 Commissioning Procedure 07 10 0 Technical Data 08 11 0 Operating Instructions 09 12 0 Troubleshooting 10 13 0 Maintenance 11 Contents ...

Page 3: ...t water through the heat exchanger This means that 1 Care must be taken in sizing both the pump and piping 2 The minimum pipe size from boiler to fan convector must be at least 1 2 inch 3 Where the unit is fitted on to a system with other emitters a separate circuit for the fan convector should be considered to provide adequate water flow 4 The system water must be above 90 F for heating mode 5 Op...

Page 4: ...hassis on to mounting screws and tighten Note Before proceeding with pipe work connections check that the unit is level If the right hand end is lower than the left then the ability to vent the unit may be restricted When water connections and electrical connections have been completed and the unit has been vented fit the outer cover and secure with fixing screws Unit A B Dimensions inches 20 14 4...

Page 5: ...t exchanger see Commissioning Procedure HI LINE Heater Cooler installations with chilled water will require provision for condensate disposal in accordance with any local regulations A drain tray is fitted for condensate collection within the unit This should be connected to a 5 8 drain pipe Note External pipe work carrying chilled water must be insulated Use a suitable sealant as necessary to ens...

Page 6: ...able socket outlet with isolating switch must be available or fitted to supply the HI LINE 8 0 Electrical Connection WARNING This appliance must be grounded The electrical installation must comply with state and local codes O O L N Brown Blue White Yellow Motor Power Board Control Board Air Sensor Water Sensor O O G Fig 4 Wiring diagram ...

Page 7: ...ng to requirements see fig 4 l Refit outer cover l Switch on electrical supply Fan Pulse Fan pulse mode causes room air to be drawn over the air temperature sensor periodically to maintain room temperatures more effectively In certain circumstances for example when units are over sized in relation to the heat loss of the room it may be necessary to turn off this function Use dipswitch 3 according ...

Page 8: ...rformance tested in accordance with BS 4856 Part 2 Flow rate 340 ltr h Relative humidity 50 Note Performance figures for heating and cooling based on a flow rate of 3 GPM For a flow rate of 1 GPM multiply by 0 87 Model Sound Pressures at 2 5m dBA 20 14 33 3 38 7 45 4 15 10 28 8 35 4 45 6 10 6 23 5 30 8 37 2 7 4 23 4 32 5 43 3 Normal Medium Boost Weight Water Content and Motor Power Model Motor Pow...

Page 9: ...ly In manual mode with water temperature control any of the 3 fan speeds can be selected and the fan will operate when the water temperature in the coil is greater than 90 F This means that heating performance can be controlled manually and the unit could be controlled via an external room thermostat The unit can be controlled using the infra red remote control handset supplied with the unit see f...

Page 10: ...he horizontal bars will reappear to show the key lock mode is activated however during this mode the handset controls remain functional To unlock the system press the On Off button for about 6 seconds until the horizontal bars disappear 10 HI LINE RC HI LINE RC Heater Cooler 12 0 Troubleshooting Once installed this fan convector becomes part of a complete heating system that generally will include...

Page 11: ...n Increase temperature set point Switch on at breaker Check all wiring and reset breaker Open valves Check boiler Programmer ON Boiler ON and set to high with central heating pump running Note Operation of fan convector can be checked by switching to manual fan setting Heating Mode Heater model only poor heating performance and or unit cycles on water sensor Possible Causes Boiler thermostat set t...

Page 12: ...heatingthroughinnovation 01 01 2012 ISSUE 2 MYSON INC 49 Hercules Drive Suite 4904 Colchester VT0446 T 802 654 7500 F 802 654 7022 info mysoninc com www mysoninc com ...

Reviews: