08

LiFePO4 Battery System for Households

07

LiFePO4 Battery System for Households

Schematic diagram of parallel connection of battery 

packs (LB24250&LB48250)

Note:

 Note: After completing the above 4 steps, arbitrarily select the positive and negative poles of one of the battery packs to output 

(the upper battery pack or the lower battery pack, you can not select the positive and negative poles of the two battery packs 

at the same time). After confirming the correct connection of the inverter, controller and battery, you can turn on any of the 

switches and use the battery group that they are now act as one bank.

Note

:

 One group of LB48V can be stacked up to 2 layers, and up to 6 in parallel connection.

48V

 

Front view 

Step 3

:

 

The schematic diagram of the parallel connection of six battery packs is shown in Figure 3.

For absolute off grid setup ,the PV awake wire need to be connected with MPPT charge controller if the 

battery pack is charged by solar modules only . The connection diagram as below :

Schematic diagram of parallel connection of battery packs(LB48200)

Summary of Contents for LB24250

Page 1: ...USER GUIDE LiFePO4 Battery System for Households LiFePO4 Battery System for Households 358 010262 00...

Page 2: ...d Settings 4 3 INSTALLATION 5 3 1 Unpacking and Inspection 5 3 2 Mounting the Unit 5 3 3 Connection for Parallel Mode 6 4 OPERATION 9 4 1 Switch On O 9 4 2 Description for LED 10 4 3 ON OFF or SOC Led...

Page 3: ...before attempting unit relocation 5 CAUTION Only quali ed solar electricians can install this device with the inverter charger 6 For optimum operation of this battery please follow required specs whe...

Page 4: ...MAX Charge Discharge Current Recommend Charge Discharge Current MAX Output Power Recommend Output Power DOD Modules Connection Communication Ingress Protection Cycle Life Working Temperature Range Net...

Page 5: ...battery wake up when the grid back connect the battery with grid use power adapter and communication line 1 shown in the package list The LB series battery support to be connected in parallel for expa...

Page 6: ...time After con rming the correct connection of the inverter controller and battery you can turn on any of the switches and use the battery group that they are now act as one bank Note One group of LB...

Page 7: ...OFF ON CELL TEMPERATURE LOW ON ON OFF ON CURRENT SENSOR ABNOMAL Sw1 SW2 SW3 SW4 Remarks 0 0 0 0 means ID 0 communication address is0x00 0x10 1 0 0 0 means ID 1 communication address is0x01 0 1 0 0 mea...

Page 8: ...tion Induce vomiting and seek medical attention If the battery pack is wet or submerged in water do not let people access it and contact your supplier for help Damaged Batteries Damaged batteries are...