GreeenTek Whole House HS 3.0 Installation, Maintenance And Operation Manual Download Page 9

Door 

Switch 

Mode 

Selector 

• II

• I

Operations

MaximumFiltration

Normal Filtration

3. General Operating Information 

PAGE 9

Function

The Whole House HEPA system is comprised of a ventilator, speed selection
switch, 3 stages of filtration and the cabinet enclosure system. The ventilator
pulls air through the pre-filter and pushes the same air threw the impregnat-
ed carbon pad for odor control and finally the last stage of filtration is the HEPA
filter which removes 99.97% of particles 0.3µm in size.

Operation Mode Options

The unit features two speeds of operation for your convenience. The speed
selection switch is located on the front of the motor assembly. At lowest speed
the unit will provide 220 CFM of clean air while at highest speed, the unit will
provide 300 CFM of clean air.  It is recommended that the unit be operated on
highest speed at all times to maximize the benefits of the HEPA filtration
system. If for some reason the filtration needs are not as important then one
might operate the unit at low speed. 
An access door is provided at the front of the unit
to permit access to the filters and speed selection
switch. Opening the latch on the right side of the
unit will permit the door to swing open. A safety
door interlock switch cuts the power to the motors
for your safety. If needed the door can be removed
from the cabinet hinges by holding the top part of
the door with one hand and     gently taping on the
bottom edge of the door with the other hand to release the door from its
hinges.

Recommended Operation

The return plenum mount model operates in conjunction with your forced air
heating/cooling system. A forced air distribution system continuously
circulates the same air inside your home. The whole house HEPA filtration
system operates on the principal of bypass filtration, which means that a
portion of the air being returned into the furnace is filtered on each pass. Over
time all the air in the home gets cleaned. It is recommended that the furnace
blower be in operation whenever the filtration system is in operation. 
For stand-alone attic installation, the HEPA filtration system must be
operated continuously whenever a part of all the system is located in an
unconditionned space to avoid condensation in the ductwork below freezing
(32°F ,0°C) 
Maintenance of the unit should be performed at regular interval to keep the
benefits of the HEPA filtration unit.

Owner’s Operation 

GUIDE

Summary of Contents for Whole House HS 3.0

Page 1: ...INST ALLA TION MAINTENANCE OPERA TION GUIDE WHOLE HOUSE HEP A FIL TRA TION SYSTEMS MODEL HS 3 0...

Page 2: ...perial Air Technologies Inc is the only manufactur er that offers you a complete range of products designed to improve indoor air quality and that provides a wide selection of accessories to facilitat...

Page 3: ...the installation of electrical products requires the services of a certified technician or electrician 22 559 mm 13 330mm 17 432 mm 17 432mm 17 432 mm 12 305 mm 11 587 294 5 mm Return Air Plenum Insta...

Page 4: ...mit the good operation of the forced air heating cooling system Optional collar system installation Usingkitno 100608theWholeHouseHEPA Filtration system can be converted to use 8 inch round collars fo...

Page 5: ...n and circulation throughout the home HEPA system must be operated continuously whenever a part or all the system is located in an unconditioned space to avoid condensation in the ductwork below freez...

Page 6: ...igure 2 2b One cut permits the clean removal of the insulation piece Step 2 Preparing ducting flairs Remove the door and filters and proceed to cut the insulation as illustrated below figure2 2a Cut t...

Page 7: ...thorities to find out whether the installation of electrical products requires the services of a certified technician or electrician GreentekTM TIPS to installer Removing the filters from the unit wil...

Page 8: ...with an extension cord If no receptacle is available please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTERACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check...

Page 9: ...selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety door interlock switch cuts the power to the motors for your safety If needed the door can b...

Page 10: ...your home GreentekTM has developed one of the first maintenance service systems in the industry The Filter Maintenance AdviserTM will remind you by e mail when the filter of your Whole House HEPA Syst...

Page 11: ...swheneverpossible Imperial Air Technologies inc 500 Ferdinand Boulevard Dieppe NB Canada E1A 6B9 Toll free 1 888 724 5211 Fax 506 388 4633 Visit us at www greentek ca ITEM 100592 0504 REV005 Protectth...

Reviews: