GreeenTek Whole House HS 3.0 Installation, Maintenance And Operation Manual Download Page 5

2.3 Types of Installation: Stand-Alone

PAGE 5

Installation 

GUIDE

Stand Alone

Attic Installation

Ideal for homes without a forced air
heating / cooling system. Allows for air 
filtration and circulation throughout 
the home.

HEPA system must be operated continuously
whenever a part or all the system 
is located in an unconditioned space to 
avoid condensation in the ductwork 
below freezing (0°C, 32°F).

Stand Alone

Basement Installation

Ducting will usually consist of one return with
grille from one side of the home, 
and one supply with grille at the opposite
end of the home. 

Summary of Contents for Whole House HS 3.0

Page 1: ...INST ALLA TION MAINTENANCE OPERA TION GUIDE WHOLE HOUSE HEP A FIL TRA TION SYSTEMS MODEL HS 3 0...

Page 2: ...perial Air Technologies Inc is the only manufactur er that offers you a complete range of products designed to improve indoor air quality and that provides a wide selection of accessories to facilitat...

Page 3: ...the installation of electrical products requires the services of a certified technician or electrician 22 559 mm 13 330mm 17 432 mm 17 432mm 17 432 mm 12 305 mm 11 587 294 5 mm Return Air Plenum Insta...

Page 4: ...mit the good operation of the forced air heating cooling system Optional collar system installation Usingkitno 100608theWholeHouseHEPA Filtration system can be converted to use 8 inch round collars fo...

Page 5: ...n and circulation throughout the home HEPA system must be operated continuously whenever a part or all the system is located in an unconditioned space to avoid condensation in the ductwork below freez...

Page 6: ...igure 2 2b One cut permits the clean removal of the insulation piece Step 2 Preparing ducting flairs Remove the door and filters and proceed to cut the insulation as illustrated below figure2 2a Cut t...

Page 7: ...thorities to find out whether the installation of electrical products requires the services of a certified technician or electrician GreentekTM TIPS to installer Removing the filters from the unit wil...

Page 8: ...with an extension cord If no receptacle is available please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTERACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check...

Page 9: ...selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety door interlock switch cuts the power to the motors for your safety If needed the door can b...

Page 10: ...your home GreentekTM has developed one of the first maintenance service systems in the industry The Filter Maintenance AdviserTM will remind you by e mail when the filter of your Whole House HEPA Syst...

Page 11: ...swheneverpossible Imperial Air Technologies inc 500 Ferdinand Boulevard Dieppe NB Canada E1A 6B9 Toll free 1 888 724 5211 Fax 506 388 4633 Visit us at www greentek ca ITEM 100592 0504 REV005 Protectth...

Reviews: