SLEEP MODE
The unit will automatically adjust room temperature during your sleep time. This slight change
in temperature will not affect your comfort level due to the natural effects that sleeping has
on the body, but it will save on energy consumption and will lower your electric bill. Press the
SLEEP button to select Sleep Mode. The SLEEP icon will appear.
In Cool or Dry modes:
If setpoint is between 61
℉
to 73
℉
, temperature will slowly increase 2
℉
per hour for 3 hours,
then maintain this setpoint for 4 hours, then reduce setpoint by 2
℉
and hold at this setpoint
until Sleep Mode is cancelled.
If setpoint is between 74
℉
to 81
℉
, temperature will slowly increase 2
℉
per hour for 2 hours,
then maintain this setpoint for 5 hours, then reduce setpoint by 2
℉
and hold at this setpoint
until Sleep Mode is cancelled.
If setpoint is between 82
℉
to 85
℉
, temperature will slowly increase 2
℉
per hour for 1 hour,
then maintain this setpoint for 6 hours, then reduce setpoint by 2
℉
and hold at this setpoint
until Sleep Mode is cancelled.
If setpoint is 86
℉
, unit will run at this setpoint for 7 hours, then reduce setpoint by 2
℉
and
hold at this setpoint until Sleep Mode is cancelled.
In Heat mode:
If setpoint is between 82
℉
to 86
℉
, the unit will slowly reduce setpoint by 2
℉
per hour for
3 hours, and then maintain this setpoint until Sleep Mode is cancelled.
If setpoint is between 69
℉
to 81
℉
, the unit will slowly reduce setpoint by 2
℉
per hour for
2 hours, and then maintain this setpoint until Sleep Mode is cancelled.
If setpoint is between 63
℉
to 68
℉
, the unit will reduce setpoint by 2
℉
, and then maintain
this setpoint until Sleep Mode is cancelled.
If setpoint is 62
℉
, the unit will run at this setpoint until Sleep Mode is cancelled.
14
Cooling Mode
Heating Mode
OPERATING INSTRUCTIONS