3.6 Up & Down Swing Setting

• There are two ways for up and down swing mode: 

simple swing and fixed swing. Under off status, press 
“SWING/ENTER” button and “ ” button simultaneously 
for 5 seconds, then switch for simple swing and fixed 
swing is done.

• When it is set to be simple swing, under on status, 

press “SWING/ENTER” button, the mode is activated, 
press the button again the mode is turned off.

• When it is set to be fixed swing, press “SWING/ENTER” 

button, the unit will circularly switch the swing mode 
according to the order shown below:

3.7 Left & Right Swing Setting

• Swing On: Press FUNCTION under on state of the 

unit to activate the swing function. In this case,   
will blink. After that, press SWING/ENTER to make a 
confirmation.

• Swing Off: When the Swing function is on, press 

FUNCTION to enter the Swing setting interface, with 

 blinking. After that, press SWING/ENTER to cancel 

this function

• Swing setting is shown as Fia.9.

NOTE:

 

1.  Use the Swing setting procedure to initiate Sleep, 

Turbo or X-fan.

2.  Once the setting is completed  press “SWING/ENTER” 

to initiate another setting or it will automatically 
cancel in 5 seconds.

3.  Not all functions are available for all units.

3.10 Sleep Setting

• Sleep on: When the unit is ON, press FUNCTION until 

the unit enters the Sleep setting interface. Press 
SWING/ENTER to confirm the setting.

• Sleep off: When the Sleep function is activated, press 

FUNCTION to enter the Sleep setting interface. Then 
press SWING/ENTER to cancel this function.

• Sleep setting is shown as Fig.11.

3.11 Turbo Setting

• Turbo function: In Turbo the high fan speed initiates 

quick cooling or heating so the room temperature 
quickly reaches set point.

• In the Cooling or Heating mode, press FUNCTION till 

the unit enters the Turbo setting interface, then press 
SWING/ENTER to confirm the setting.

• When the Turbo function is activated, press FUNCTION 

to enter the Turbo setting interface and then press 
SWING/ENTER to cancel this function.

• Turbo function setting is as shown in Fig. 12.

Wired Controller (Continued)

Summary of Contents for Slim Duct B Series

Page 1: ...0V1BD MODELS CAT NO GREE_SLIM DUCT B_OWNERS_11102022 Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference To download an electric version of this manual visit https gree comfort dev web app system documentation ...

Page 2: ...f other GREE installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference TABLE OF CONTENTS Nomenclature 3 Safety Precautions 4 Part Names 6 System Functions 7 Wired Controller 9 Operation of Remote Contoller 16 Care and cleaning 21 Troubleshooting 22 Energy Saving Tips 23 Warranty 24 Owner s manual FAQ ...

Page 3: ...ctrical Rating 230V 208 230V 1PH 60Hz Style Color Designation Product Type O Outdoor Units C Indoor Cassette D Indoor Slim Duct F Indoor Floor Ceiling Model Type HP Heat Pump Capacity 09 9 000 BTUH 12 12 000 BTUH 18 18 000 BTUH 24 24 000 BTUH Series Designation CAS Cassette DUCT Slim Duct FLR Floor Ceiling CONS Mini Console ...

Page 4: ...enhanced installation reliability or operation NOTE Your actual air conditioning heating system and related devices may differ from the images shown in this manual WARNING This appliance is not intended for use by children without responsible adult supervision Proper care should be taken to ensure safety WARNING Heat pumps air conditioners heating equipment should be installed started up and servi...

Page 5: ...ng be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Do not use or place any flammable combustible or noxious substance next to the unit In the event of a failure burning smell etc immediately disconnect all electrical power to indoor and outdoor units Never try repairing the system yourself contact a qualified service technician for all repairs SAFET...

Page 6: ...ote Controller 6 Interconnection Cable 7 Front Panel 8 Service Cover 9 Liquid Pipe 10 Gas Pipe 11 Drain Hose 12 Outdoor Power Supply Outdoor Unit 3 1 Air outlet Air outlet Air inlet Air inlet 2 11 10 9 8 12 7 CAUTION 6 4 5 4 SYSTEM PARTS Indoor Unit Part Name 1 Gas Liquid Pipes 2 Electric Box 3 Interconnection Cable 4 XK 19 Wired Tether Controller 5 Remote Controller 6 Interconnection Cable 7 Fron...

Page 7: ... then adjusts airflow and temperature accordingly for ultimate personal comfort TURBO MODE Use Turbo Mode for situations where you wish to achieve the desired room temperature in the shortest possible time This mode runs the unit at ultra high speeds for quickest results VACATION MODE FREEZE GUARD Vacation mode freeze guard sets the unit to 46 F 8 C in heating to keep the temperature in the space ...

Page 8: ...meters are stored in non volatile memory These parameters are retained during a power failure When power is returned the Slim Duct B Series system will automatically return to the last operating mode INTELLIGENT DEFROST Intelligent Defrost function increases room comfort and saves energy by eliminating unnecessary defrost cycles In heating mode the unit will monitor the outdoor coil for frost buil...

Page 9: ...AND function is set Display when WiFi function is set Lock out status display when lock out function is set Display when up and down swing function is set Icon of follower controller it will display when follower wired controller is set this function is unavailable for this unit The fan speed set currently including auto low medium low medium medium high high and turbo This function is unavailable...

Page 10: ...the lock state in which case any other buttons won t respond Repress them for 5s to quit this state Under OFF state the Celsius and Fahrenheit scales can be switched by pressing MODE and for 5s Under OFF state go to the commissioning status by pressing FUNCTION and TIMER for five seconds and let 00 displayed on he temperature display area by pressing MODE then adjust the options which is shown on ...

Page 11: ...In Cooling Dry Fan or Heating mode the temperature setting range is 61 F 86 F 16o C 30o C IntheAutomode thesettingtemperatureisunadjustable 3 4 Fan Setting Under the ON State of the unit each time you press FAN the fan speed will change circularly as shown in Fig 7 3 5 Timer Setting Under the T ON T OFF state of the unit press Timer to set timer off on Timer ON setting press Timer and then LCD wil...

Page 12: ...ction Swing setting is shown as Fia 9 NOTE 1 Use the Swing setting procedure to initiate Sleep Turbo or X fan 2 Oncethesettingiscompleted press SWING ENTER to initiate another setting or it will automatically cancel in 5 seconds 3 Not all functions are available for all units 3 10 Sleep Setting Sleep on When the unit is ON press FUNCTION until the unit enters the Sleep setting interface Press SWIN...

Page 13: ...f indoor unit will be automatically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to activate When the X fan function is activated press and hold FUNCTION until X FAN appears then press SWING ENTER to cancel X fan function setting is as shown in Fig 15 NOTE 1 When the X fan function is activated turn...

Page 14: ...Demand setting interface Press SWING ENTER to confirm the setting I Demand off When the I Demand function is activated press FUNCTION to enter the I Demand setting interface After that press SWING ENTER to cancel this function NOTE 1 This function is only available in cooling mode 2 When this function has been set set temperature is displayed as SE In this case the unit will adjust the set tempera...

Page 15: ...ve seconds to go to the commissioning status Under this status adjust the display in the temperature display area to 00 through the button MODE and then adjust the option of the temperature sensor in the timer display area through the button or 1 Indoor ambient temperature is sensed at the return air inlet 01 in the timer display area 2 Indoor ambient temperature is the sensed at the wired control...

Page 16: ...B SERIES OWNERS MANUAL INDOOR UNIT 16 OPERATION OF REMOTE CONTROLLER Buttons on remote controller Introduction for icons on display screen Remote lock out DISCLAIMER All functions are not available for this unit ...

Page 17: ...erate in a fan only mode no heating or cooling and all indicators will be off When All indicators are off press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting HEAT the air conditioner operates under heat mode Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle NOTE When selecting the HEAT mo...

Page 18: ...e Select and fan modulation will stop at that fixed position Horizontal louver will stop at the fixed position Select will not modulate but blow at a fixed angle Hold button more than 2s to set your required swing angle When reaching your desired angle release the button NOTE Pressing this button continuously for more than 2s the louver will swing back and forth from up to down release the button ...

Page 19: ...d on the remote controller When set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature Press this button again to cancel I FEEL function and will disappear Put the remote controller near the user when this function is set Avoid putting the remote controller near an ob...

Page 20: ... either Sleep function and 46 F 8 C heating function can t operate at the same time If 46 F 8 C heating function has been set under heat mode pressing the SLEEP button will cancel 46 F 8 C heating function If sleep function has been set under heat mode initiating the 46 F 8 C heating function will cancel SLEEP function Remote lock out Press or simultaneously to turn on or turn off Remote lock out ...

Page 21: ...vices all power supply circuits must be disconnected Clean the filter and the outside panels with warm water and do not use excessive heat to dry NOTE 1 Do not operate the air conditioner with the filter uninstalled otherwise dust would come into the unit 2 Do not remove the air filter except for cleaning Unnecessary handling may damage the filter 3 Donotcleantheunitwithgasolene benzene thinner po...

Page 22: ...on the HEAT mode In order to prevent cold air from blowing out it may take several minutes before the fan starts This is normal Air conditioner isn t coming on Power failure Wait until power recovery Loose wiring Contact your contractor or an electrician Circuit breaker has tripped or fuse is burnt out Ask professional to replace circuit breaker or fuse Wiring is overheating or needs repair Ask pr...

Page 23: ...ss clippings and other debris can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs the airflow needs to be removed or rearranged accordingly 6 Try 75 degrees 75 F is a good point for an air conditioner to run at its optimal performance level Even a 5 degree change in temperature can make your unit use up to 40 more energy 7 Lighting Turning li...

Page 24: ...______________________ Serial No ___________________________________ Outdoor Model No _____________________________ Serial No ___________________________________ Owner Name _________________________________ Date of Installation ___________________________ Address of Installation Installing Contractor ____________________________________________________ Address _____________________________________...

Page 25: ...U S CONTACT INFORMATION TRADEWINDS LLC E mail info twciimate com Contractor Support 888 850 7928 I Mon Fri 8 AM 5 PM EST G R E E C O M F O R T C O M ...