78
Fault Displays
18,000 and 24,000 btuh units
Malfunction
Name
Indoor Unit Displaying Method
Outdoor Unit Display (LED)
A/C Status
Malfunctions
Dual-8
Code
Display
Indicator Display (during
blinking, ON 0.5s and OFF 0.5s
Indicator has 3 kinds of display status
and during blinking, ON 0.5s and OFF
0.5s
Running
LED
Cooling
LED
Heating
LED
D40/
D5
D41/
D6
D42/
D16
D43/
D30
Zero crossing
malfunction
of outdoor
unit
U9
n
n
¶
o
During cooling
operation,
compressor will
stop while indoor
fan will operate;
during heating the
complete unit will
stop operation
Replace outdoor
control panel AP1
Limit/
decrease
frequency
due to anti
freezing
FH
n
n
n
o
All loads operate
normally, while
operation frequency
for compressor is
decreased
Poor air-return in
indoor unit or fan
speed is too low
o
= OFF
n
= Illuminated
¶
= Blink