6
Overload
malfunction
E8
During cooling or
drying operation,
indoor fan operates,
while compressor,
outdoor fan and
water-striking
motor stop. “E8” is
displayed.
1. The environment is formidable.
2. Heat exchangers are too dirty or the air
inlet/outlet is blocked.
3. Fan motor doesn't work at a normal
fan speed; fan speed is too low or the fan
doesn't run.
4. Compressor doesn't work normally.
Strange noise or leakage occurs.
Temperature of the shell is too high.
5. System is blocked inside(dirt block, ice
block, oil block, Y-valve not fully open).
6.Temperature sensor of main board can't
detect correctly.
Refer to
maintenance
flowchart.
7
Malfunction
of detecting
plate(WIFI )
JF
Loads operate normally, while the unit
can’t be normally controlled by APP.
1. Main board of indoor unit is damaged;
2. Detection board is damaged;
3. The connection between indoor unit
and detection board is not good;
Refer to
maintenance
flowchart.
8
Defrosting
Heating indicator
off for 0.5s and
then blinks for
10s
Not the error code. It’s the status
code for the operation.
Refer to
maintenance
flowchart.
(1) When multiple malfunction occurs, error codes will be displayed in turns (when it detected that AD value of temperature sensor is ≥
250 or ≤5 for consecutive 5s, it will enter into the temperature sensor protection);
(2) Under on status, when there’s temperature sensor malfunction, the compressor stops operation. Under non-heating mode, the
fan operates according to set fan speed; under heating mode, the fan stops operation after blowing residual heat. Under off status,
malfunction won’t be displayed, but it can receive remote control signal and button signal. When there’s above malfunction under off
status, turn on the unit and it will only display the malfunction. The compressor won’t stop operation. Under non-heating mode, the fan
operates according to set fan speed; under heating mode, the fan stops operation.