Service Manual
Technical Information
9
Model
GJH18AE-K6NRNR1A
GJH18AE-K6NRNR1B
GJH18AE-K6NRNB3A
GJH18AE-K6NRNB9A
GJH21AE-K6NRNR1A
GJH21AE-K6NRNR1B
GJH21AE-K6NRNB3A
GJH21AE-K6NRNB9A
Product code
CC053010600
CC053016800
CC053025900
CC053027700
CC053010900
CC053016100
CC053025700
CC053027800
Power
Supply
Rated Voltage
V~
220-240
220-240
Rated Frequency
Hz
50
50
Phases
1
1
Cooling Capacity
W
5300
6000
Heating Capacity
W
4800
5515
Cooling Power Input
W
1600
1810
Heating Power Input
W
1450
1690
Cooling Power Current
A
7.87
7.87
Heating Power Current
A
7.35
7.35
Rated Input
W
2100
2600
Rated Current
A
10.7
13.2
Air Flow Volume(H/M/L)
m
3
/h
780/720/660
840/780/720
Dehumidifying Volume
L/h
2.2
2.2
EER
W/W
3.31
3.31
COP
W/W
3.31
3.26
SEER
W/W
/
/
HSPF
W/W
/
/
Application Area
m
2
23-34
27-42
Fan Motor Speed(H/M/L)
rpm
1060/980/900
1160/1050/940
Output of Fan Motor
W
190
170
Fan Motor RLA
A
0.8
0.8
Fan Motor Capacitor
μF
7
7
Climate Type
T1
T1
Isolation
I
I
Moisture Protection(Outdoor)
IPX4
IPX4
Permissible Excessive Operating Pressure for the
Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating Pressure for the
Suction Side
MPa
2.5
2.5
Dimension (WXHXD)
mm
660X428X770
660X428X770
Dimension of Carton Box (LXWXH)
mm
860X736X490
860X736X490
Dimension of Package (LXWXH)
mm
863X739X505
863X739X505
Net Weight
kg
64
65
Gross Weight
kg
69
70
Refrigerant
R32
R32
Refrigerant Charge
kg
1.08
1.05