12
Outdoor Units_Heat Recovery
Ton
18
20
22
Model
-
GMV-Q216WM/B-F(U)
GMV-Q240WM/B-F(U)
GMV-Q264WM/B-F(U)
Module combination
-
GMV-Q96WM/B-F(U)+
GMV-Q120WM/B-F(U)
GMV-Q120WM/
B-F(U)+
GMV-Q120WM/B-F(U)
GMV-Q72WM/B-F(U)+
GMV-Q96WM/B-F(U)+
GMV-Q96WM/B-F(U)
Performance
Nominal Cooling
Capacity
Btu/h
216000
240000
264000
kW
63.3
70.3
77.4
Rated Cooling
Capacity
Btu/h
201000
222000
247000
Nominal Heating
Capacity
Btu/h
243000
270000
297000
kW
71.2
79.1
87.1
Rated Heating
Capacity
Btu/h
226000
252000
275000
Cooling Power Input
kW
7.30+9.58
9.58+9.58
5.45+7.30+7.30
Heating Power Input
kW
7.85+10.42
10.42+10.42
5.80+7.85+7.85
Sound Pressure
Level
dB(A)
-
-
-
Power Supply
-
208/230V 3~ 60Hz
Compressor
Type
-
Inverter scroll type
Inverter scroll type
Inverter scroll type
Number
N
1+2
2+2
1+1+1
Motor Output
①
kW
-
-
-
Starting Method
-
Inverter
Inverter
Inverter
Operating Range
-
-
-
-
Refrigeration Oil
Brand
-
FVC68D or FV-68H
FVC68D or FV-68H
FVC68D or FV-68H
Fan
Type×Quantity
-
Propeller×(2+2)
Propeller×(2+2)
Propeller×(2+2+2)
Motor output
W
750×2+750×2
750×2+750×2
750×2+750×2+750×2
Starting method
-
Inverter
Inverter
Inverter
Air flow rate
m
3
/h
14000+14000
14000+14000
14000+14000+14000
cfm
8240+8240
8240+8240
8240+8240+8240
Max. external static
pressure
Pa
82
82
82
in.W.G
0.328
0.328
0.328
Ambient
temperature
range
Cooling
°C
-5~52
-5~52
-5~52
℉
23~125.6
23~125.6
23~125.6
Heating
°C
-20~24
-20~24
-20~24
℉
-4~75.2
-4~75.2
-4~75.2
Refrigerant
Refrigerant Type
-
R410A
R410A
R410A
Refrigerant Charge
Volume
kg
11.2+11.7
11.7+11.7
9.6+11.2+11.2
lbs.
24.69+25.79
25.79+25.79
21.16+24.69+24.69
Control
-
EXV
EXV
EXV
Pipe
Connection
Low pressure Gas
Pipe Size
mm
28.6
34.9
34.9
in.
1 1/8
1 3/8
1 3/8
high pressure gas
pipe
mm
28.6
28.6
28.6
in.
1 1/8
1 1/8
1 1/8
Liquid Pipe Size
mm
15.9
15.9
19.05
in.
5/8
5/8
3/4