Operating Procedures / Photos
Unsolder the pipeline connecting with valves ( to
prevent soldering gun from burning out the
chassis). Unscrew 2 bolts fixing gas valve ,and
then unsolder the weld spot between pipeline and
gas valve to remove gas valve. Unscrew the 2
bolts fixing liquid valve, and then unsolder the
soldering spot between pipeline and liquid valve
to remove liquid valve.
(Note:During unsoldering ,wrap the valves with
wet cloth avoid damage for high temperature.)
4. Disassemble Electric Box Sub-assy
Unscrew the 2 screws fixing electric box to pull
out the connection line between fan motor,
compressor,four-way valve, and then lift the elec-
tric box to take it out.
6. Disassemble Gas and Liquid Valves
Bolts
L i q u i d
Valve
Gas Valve
Screws
Electric box
5. Disassemble Right side plate
Unscrew the screw of the right side plate, then
take down the right side plate.
Right side plate