Removal Procedure
94
Steps
Procedure
10. Remove axial flow blade
11. Remove motor and motor support
12. Remove electric box assy
axial flow blade
motor support
motor
electric box assy
Remove the nut on the blade and then remove the
axial flow blade.
Remove the 4 tapping screws fixing the motor and
disconnect the leading wire insert of the motor.
Then remove the motor. Remove the 2 tapping
screws fixing the motor support and chassis, and
then lift the motor support to remove it.
Remove the screws fixing the electric box assy and
the middle isolation sheet, and then lift the electric
box assy to remove it.