Troubleshooting
75
AC Current Protection
(Input Side)
PA
Flash 3 times
Flash 3 times
Flash 3 times
PA
PA
Outdoor
Temp Drift Protection
PE
Flash 3 times
Flash 3 times
Flash 3 times
PE
PE
Outdoor
Drive Board Ambient
Temp Sensor Error
PF
Flash 3 times
Flash 3 times
Flash 3 times
PF
PF
Outdoor
Low Voltage Protection
PL
Flash 3 times
Flash 3 times
Flash 3 times
PL
PL
Outdoor
Over Voltage Protection
PH
Flash 3 times
Flash 3 times
Flash 3 times
PH
PH
Outdoor
AC Input Voltage Anomaly
PP
Flash 3 times
Flash 3 times
Flash 3 times
PP
PP
Outdoor
Charging Circuit Error
PU
/
/
Flash 17
times
PU
PU
Outdoor
Oil Return for Heating
or Defrosting
H1
/
/
Flash once
H1
Outdoor
Forced Defrosting
H1
Quick Flashing
/
/
H1
H1
Outdoor
Compressor Overheat Protection
H3
/
/
Flash 3 times
H3
H3
Outdoor
IPM Protection
H5
/
/
Flash 5 times
H5
H5
Outdoor
Motor Desynchronizing
H7
/
/
Flash 7 times
H7
H7
Outdoor
PFC Error
Hc
/
/
Flash 6 times
Hc
Hc
Outdoor
/
L9
Flash 20 times
/
/
L9
L9
Outdoor
Startup Failure
Lc
/
/
Flash 11 times
Lc
Lc
Outdoor
Phase Loss
Ld
Flash 3 times
Flash 3 times
Flash 3 times
Ld
Ld
Outdoor
Compressor Stalling
LE
Flash 3 times
Flash 3 times
Flash 3 times
LE
LE
Outdoor
Over-Speed
LF
Flash 3 times
Flash 3 times
Flash 3 times
LF
LF
Outdoor
/
A5
Flash 3 times
Flash 3 times
Flash 3 times
oE
A5
Outdoor
/
A7
Flash 3 times
Flash 3 times
Flash 3 times
oE
A7
Outdoor
/
EE
/
/
/
/
/
Outdoor
/
En
Flash 3 times
Flash 3 times
Flash 3 times
En
En
Outdoor
/
EU
/
Flash 6 times
Flash 6 times
EU
EU
Outdoor
/
F6
/
Flash 6 times
/
F6
F6
Outdoor
/
F8
/
Flash 8 times
/
F8
F8
Outdoor
/
F9
/
Flash 9 times
/
F9
F9
Outdoor
/
FH
/
Flash twice
Flash twice
FH
FH
Outdoor
/
HE
/
/
Flash 14 times
HE
HE
Outdoor
/
LP
Flash 19 times
/
/
LP
LP
Outdoor
& Indoor
/
U1
/
/
Flash 12 times
U1
U1
Outdoor
/
U3
/
/
Flash 20 times
/
/
Outdoor
Communication Line
Misconnected or
Expansion Valve Error
dn
Flash 3 times
Flash 3 times
Flash 3 times
dn
dn
Outdoor
7KHZRUGVLQJUD\PHDQVWKHFRUUHVSRQGLQJIXQFWLRQLVXQDYDLODEOH