Installation of Indoor Unit
Installation of Mounting Plate
1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of
condenser water.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by every screw.
Fig.5
1.
2.
3.
Installation of Drain Hose
Connect the drain hose to the outlet pipe of the indoor unit.
Bind the joint with rubber belt.
Put the drain hose into insulating tube.
Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain
hose
downward
slightly for smooth drainage of condensing water.
outlet pipe of
indoor unit
insulating tube
connected
insulating tube
drain hose
outlet pipe of
indoor unit
rubber belt
rubber belt
Ф55
or Ф70
Drill Piping Hole
1.Slant the piping hole (Ф55 or Ф70) on the wall slight
ly downward to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Wall pipe
Seal pad
25
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
rubber belt
24
、
28K UNIT:
18K UNIT:
130
100
165
240
36
36
Φ70
Φ70
747
330
330
12K UNIT:
865
542
175
298
206
23
12
116
140
40
Φ55
Φ55
319
158
144
685
575
189
281
55
55
90
155
Φ70
1018
155
13
90
55
55
Φ70
35