Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
Procedure
Step
1.Remove big handle
2. Remove top cover
top cover
big handle
valve cover
Before disassamble
.
Remove the screws fixing
big handle
、
valve
cover and then remove them.
Remove the screws fixing top panel and
then remove the top panel.