background image

6

(Display content or position may be different from above 

graphics, please refer to actual products)

Parts name

Indoor Unit

air inlet

panel

filter

aux.button

horizontal louver
air outlet

heating 

indicator

temp.

indicator

cooling

indicator

power

indicator

receiver

window

drying

indicator

display

remote control

Actual product may be different from above graphics, please refer to actual 

products.

NOTICE:

Summary of Contents for GWH09TA-K3DNA1B/I

Page 1: ...lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version Thank you for choosing our product For proper operation please r...

Page 2: ...I GWH12TB K3DNA1B I GWH18TC K3DNA1B I DRED GWH24TD K3DNA1C I DRED GWH28TD K3DNA1B I DRED DRED DRED GWH28TD K3DNA2B I DRED GWH18TC K3DNA2B I DRED GWH12TB K3DNA2B I DRED GWH24TD K3DNA2C I DRED GWH09TA...

Page 3: ...nsion diagram 23 Tools for installation 24 Selection of installation location 24 Requirements for electric connection 25 Installation Installation of indoor unit 26 Check after installation 31 Test an...

Page 4: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 5: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Page 6: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Page 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Page 8: ...y or damage If you need to relocate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for child...

Page 9: ...Parts name Indoor Unit air inlet panel filter aux button horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display remote...

Page 10: ...MODE button ON OFF button FAN button button MODE button 3 4 2 1 before opening cover after opening cover Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON TIME...

Page 11: ...mode can be selected circularly Auto button 4 Presetting temperature can be increased Press this button the temperature can be set up continuously press this button and hold for two seconds the relat...

Page 12: ...e time value of numerical section every press of that button the value will be increased or decreased 1 minute Hold pressing or button 7 Press this button to set swing angle which circularly changes a...

Page 13: ...the fourth time to start healthy function LCD display Press this bu tton again to repeat the operation above NOTE This function is applicable to partial of models or outdoor ambient temperature on in...

Page 14: ...etting te mperature increased 2 the unit will run at this setting temperature In Heat mode sleep status after run for one hour the setting temperature will decrease 1 2 hours setting temperature will...

Page 15: ...7 20 after Sleep function started up the temperature will decrease 1 in every hour after 2 decreased this temperature will be maintained 3 Under the initial presetting temperature 21 27 after Sleep fu...

Page 16: ...er is locked the icon will be displayed on it in which case press any button the mark will flicker for three times If the keyboard is unlocked the mark will disappear About swing up and down 1 Press s...

Page 17: ...atus could be optional and turned off 1 Under cooling mode indoor fan operates at notch 4 speed 10 minutes later or when indoor ambient temperature 28 indoor fan will operate at notch 2 speed or quiet...

Page 18: ...TURBO button can realize the ON and OFF of TURBO function 1 Press the back side of remote controller marked the cover of battery box along the arrow direction 2 Replace two 7 AAA 1 5V dry batteries a...

Page 19: ...under auto mode panel Clean and maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with wate...

Page 20: ...the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly The filter should be cleaned ever...

Page 21: ...e pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for reco...

Page 22: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 23: ...door temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set t...

Page 24: ...t again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or tu...

Page 25: ...e s abnormal sound during operation Circuit break trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal conditions it may c...

Page 26: ...23 Installation dimension diagram At least 15cm Space to the wall At leas t 250c m At leas t 15cm At least 300cm Spa ce to the ceili ng Space to the obstruction At least 15cm Space to the wall...

Page 27: ...ld be able to withstand the weight of indoor unit and won t increase noise and vibration 6 The appliance must be installed 2 5m above floor 7 Don t install the indoor unit right above the electric app...

Page 28: ...ent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance sha...

Page 29: ...se drill another fixing hole nearby 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame show...

Page 30: ...h 2 When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear ri...

Page 31: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Page 32: ...oner with plug the plug should be reachable after finishing installation For the air conditioner without plug an circuit break must be installed in the line The circuit break should be all pole partin...

Page 33: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 34: ...unit grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet I...

Page 35: ...rant charging amount per meter When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is d...

Page 36: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 37: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000061...

Reviews: