31
Installation Manual
7.6 Installation and Maintenance of Healthy Filter
7.5.2 Operation Test
1.Before Operation Test
(1)Do not switch on power before installation is finished completely.
(2)Electric wiring must be connected correctly and securely.
(3)Cut-off valves of the connection pipes should be opened.
(4)All the impurities such as scraps and thrums must be cleared from the unit.
2.Operation Test Method
(1)Switch on power and press "ON/OFF" button on the wireless remote controllerto start the operation.
(2)Press MODE button to select the COOL, HEAT (Cooling only unit is not available), FAN to check whether the operation
is normal or not.
Fig. a
filter
Air filter
Fig. b
Fig. c
Healthy
7.6.1 Installation of Healthy Filter
1.Fig. bFig. c Lift up the front panel from the two ends of it, as the arrow direction shown.
Thenpull the air filter out.(as shown Fig.a)
2.Attach the healthy filter onto the air filter, (as shown Fig.b).
3. Mount the air filter properly along the arrowdirection in Fig.c, and then close the panel
cover.
7.6.2 Cleaning and Maintenance
7.6.3 Service Life
Remove the healthy filter before cleaning and reinstall it after clean according to the installation instruction, but can't
with brush or hard things. After washing, be sure to shake off remaining water and dry in the shade.
The healthy filter commonly has its usage lifetime for one year under normal condition. As for silver ion filter, it is invalid
when its surface becomes black (green). This supplementary instruction is provided for reference to the unit with
healthy filter. If the graphics provided herein is different from the physical goods, the latter one shall prevail. The quantity
of healthy filters shall be based on the actual delivery.