5HPRYDO3URFHGXUH
1
2
1
2
1
2
assy
5
Step
Procedure
Remove front case
Loosen clasps between vertical louver
and rear case. Then remove vertical
louver.
Remove screw caps on front case and
then the screws on front case. Loosen
clasps of front case. Then remove front
case.
Remove electric box
Loosen clasps of electric box and then
remove electric box cover 1.
Remove connection screws between
electric box and rear case. Unplug wiring
terminal and loosen clasps. Remove
connection screws between ground wire
and evaporator. Unplug indoor temp
sensor and then remove electric box.
vertical louver
vertical louver
front case
screws
electric box cover 1
electric box