98
Installation and Maintenance
Service Manual
Procedure
Steps
compressor
Remove the 2 screws fixing the gas valve
and unsolder the welding joint between
the gas valve and the air-return pipe to
remove the gas valve. (NOTE: Discharge
the refrigerant completely before
unsoldering; when unsoldering, wrap the
gas valve with a wet cloth completely to
avoid damage to the valve caused by high
temperature).
Remove the 2 screws fixing the liquid
valve and unsolder the welding joint
connecting the liquid valve to the Y-type
pipe to remove the liquid valve.
b
Unsolder pipes connecting with
compressor.
c
Remove the 3 foot nuts on the compressor
and then remove the compressor.
d
4-way valve
cut-off valve
nuts
Unsolder the welding joint connecting the
capillary, valves and the outlet pipe of
condenser to remove the capillary. Do not
block the capillary with welding slag
during unsoldering.
11. Remove compressor
a
Summary of Contents for GWH09AGA-K6DNA1A/I
Page 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Page 18: ...15 Technical Information Service Manual 841 912 309 373 349 582 646 Unit mm 24K...
Page 102: ...99 Installation and Maintenance Service Manual 18K...
Page 103: ...100 Installation and Maintenance Service Manual...
Page 104: ...101 Installation and Maintenance Service Manual...
Page 105: ...102 Installation and Maintenance Service Manual Capillary Sub assy...
Page 107: ...104 Installation and Maintenance Service Manual screws Rear Grill...
Page 108: ...105 Installation and Maintenance Service Manual...
Page 109: ...106 Installation and Maintenance Service Manual...
Page 110: ...107 Installation and Maintenance Service Manual...
Page 111: ...108 Installation and Maintenance Service Manual...