background image

右后

25

4.

2.

3.

1.

⑴ 
⑵ 

 

 

 

After tighten the screw, slight pull the wire and confirm whether is it firm or not.

 

 

The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that 

1.

2.

Install indoor unit

NOTE:

When connecting the electric wire if the wire length is not enough, please contact with

the authorized service shop to buy a exclusive electric wire that is long enough and the

joint on the wire are not allowed.

The electric wiring must be correctly connected, wrong connection may cause spare parts malfunction.

Tighten the terminal screw in order to prevent loose.

If the earth wire is wrong connection, that may cause electric shock.

the dust, moisture may enter in or the connection terminal will be affected by outside force,

and will cause fire or electric shock.

Install the indoor unit

The piping can be lead out from right, right rear, left,left rear.

When routing the piping and wiring from the left
or right side of indoor unit, cut off the tailings
from the chassis in necessary(Show in Fig.7)

Cut off the tailings 1 when routing the wiring only;

Cut off the tailings 1 and tailings 2 when routing
both the wiring and piping. 

Take out the piping from body case, wrap the piping
electric wire, water pipe with tape and pull them
through the piping hole (As show in Fig.8)

Hange the mounting slots of the indoor unit on the upper tabs 

of the rear panel and check if it is firm enough.(As show in Fig.9)

The height of the installed location should be 2.3 m

or more from the floor.

Install the connection pipe

Align the center of the piping flare with the relevant valve.

Screw in the flare nut by hand and then tighten the

nut with spanner and torque wrench refer to the following:

NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention
to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too

much, otherwise it may cause leakage.

Spanner

Torque
wrench

Piping

Taper nut

Indoor unit piping

Fig.9

Mounting

plate

Fixing hook Mounting

baord

Right

Right rear

Fig.8

Left rear

Left

Fig.7

Tailing 1

Tailing 2

Finally wrap it
with tape

Gas side piping
insulation

Water drainage pipe

Liquid side

Piping insulation

Gas side pipe External connection

electric wire

Liquid side piping

          (N·m)

Ф

6

Ф

9.52

Ф

12

31~35

15~20

50~55

Ф

16

60~65

Ф

19

70~75

Hex nut diameter

Tightening torque

Fig.6(

b

)

blue

black

brown

yellow-green

violet

orange

blue

black

brown

yellow-green

signal control wire

Power connection wire

Power connection wire

For 

GWCN24JDNK1A1A

GWHN24JDNK1A1A

Summary of Contents for GWCN09JANK1A1A

Page 1: ...me socket It can cause an electric shock or fire Don t operate the air conditioner with wet hands It can cause an electric shock to pull out the power supply It can cause an electric shock or fire Whe...

Page 2: ...onditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfun...

Page 3: ...e horizontal air flow Louver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blo...

Page 4: ...indoor heat exchanger temperature is decreased below 0 degree the indoor unit microcomputer will stop compressor and outdoor fan running to protect the unit Working principle and special functions for...

Page 5: ...ehumidifying for a long time there will be dew dripping off near the air outlet Gentle Breeze In the following situation the indoor unit may blow gentle breeze and the guide louver rotate to a certain...

Page 6: ...oor unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Displayer Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Heating Cooling Slie...

Page 7: ...button the unit will be turned on press it once more the unit will be turned off Sleep function will be canceled while unit off HEAT initial value is 28 Under other modes the initial value is 25 82 7...

Page 8: ...button and send the order that the signal will be displayed all the time The temperature adjustment is unava ilable under the Auto mode but the order can be sent if pressing this button Temperature o...

Page 9: ...en repress this button this function will be turned off Press this button to set swing angle which circularly changes as below OFF This remote controller is universal If it receives threes kinds of fo...

Page 10: ...later the temperature will be decreased 1 after that the unit will keep on running under this temperature 2 When setting the initial temperature 24 2 7 after turned on Sleep function the temperature w...

Page 11: ...til 8hours later temperature setting finished sleep curve setting finished at this time the remote control will resume the original timer display temperature 88 will display the corresponding temperat...

Page 12: ...ortable About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temp approachs the preset temp as soon as possible About AUTO...

Page 13: ...ler is under off status press mode button and blow button simultaneously in order to enter or cancel this new function If the unit is under defrost mode dual eight position on remote controller will d...

Page 14: ...liquid damage the wireless remote control It should be placed where is 1m away from the TV set or stereo sound sets The operation should be in its receiving range If the remote control cannot operate...

Page 15: ...splayer indicator light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the...

Page 16: ...r unit in order to avoid hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dus...

Page 17: ...t the dealer 1 Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Page 18: ...blem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is ru...

Page 19: ...sert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged I...

Page 20: ...ng in the room Air switch or protection switch often breaks Carelessy splash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and disconnect Afte...

Page 21: ...s For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong heat sources vapors flammable gas or volatil...

Page 22: ...wo color wire in air conditioner is earthing wire and cannot be used for other purpose It can not be cut off and be fixed by screw otherwise it would cause electric shock The earth resistance should a...

Page 23: ...obstruction Space to the wall Air outlet side Space to the wall Air inlet side Above Above Above Above Above A cm 34 2 55 0 B cm 18K Installation dimension of outdoor units Applicable units Outdoor u...

Page 24: ...thstand the weight of an adult of 60kg further more the weight should be evenly shared by each screw Install the piping hole 1 Drill a hole 55 inclined outwards after confirmation of piping hole s loc...

Page 25: ...ping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 Hange the mounting slots of the indoor unit on the upper tabs of the rear...

Page 26: ...and connection and fixing place on the lead wire Handle Power connection wire Signal control wire Power connection wire Cool only type Heat pump type blue black brown yellow green violet orange blue b...

Page 27: ...um gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pum...

Page 28: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Page 29: ...ice Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Test operation and check after installation This symbol stands for the items should be forbidden Th...

Page 30: ...pt Post code 519070 OWNER S MANUAL Thank you for choosing GREE air conditioner For correct operation please read this owner s manual carefully before operating the unit and keeps it carefully for cons...