58
Installation and Maintenance
Service Manual
Steps
Procedure
13.Remove left side plate
14.Remove four-way valve sub-assy
15.Remove compressor
remove the plate.
Welding cut the weld spots of suction/discharge
pipe, condensing pipe inlet and the connection
pipe of big valve, to remove the four-way valve.
(Note: Do discharge the refrigerant clearly
before welding.)
compressor, lift the compressor to remove it.
left side plate
four-way valve sub-assy
compressor