5HPRYDO3URFHGXUH
11. Remove Compressor
1 Remove the 2 screws fixing the gas valve.
Unsolder the welding spot connecting gas valve
and air return pipe and remove the gas valve.
(Note: it is necessary to warp the gas valve when
unsoldering the welding spot.) Remove the 2
screws fixing liquid valve. Unsolder the weld-
ing spot connecting liquid valve and remove the
liquid valve.
2 Remove the 3 footing screws of the compressor
and remove the compressor.
Compressor
Gas valve
Liquid valve
10. Remove Clapboard Sub-Assy
Loosen the screws of the Clapboard Sub-Assy .
The Clapboard Sub-Assy has a hook on the
lower side. Lift and pull the Clapboard Sub-Assy
to remove.
Clapboard Sub-Assy