9
Technical Information
Service Manual
2.2 Capacity Curve in Different Outdoor Temperature
2.3 Cooling and Heating Data Sheet in Rated Frequency
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Cooling:
Heating:
40
50
60
70
80
90
10 0
11 0
32 33 34 35 36 37 38 39 40 41 42 43 44 45
Outdoor temp.(°C)
C
apacity rati
o(%
)
Conditio n
Indoor:DB27
°C
WB19
°C
Indoor air flow: Super High
Pipe length: 5m
Capacity rati
o
(%)
15
7
-7 -5
0 2
24
0
20
40
60
80
100
120
-10
5
10
Outdoor Temp.(°C)
Condition Heating
Indoor:DB20
°C
Indoor air flow: Super High
Pipe length: 5m
Rated cooling condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat exchanger Fan speed of
indoor unit
Fan speed
of outdoor
unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/24
09K
0.9~1.1
in:10~14
out:11~14
in:72~83
out:35~40
Super High
High
Rated heating condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat exchanger Fan speed of
indoor unit
Fan speed
of outdoor
unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/-
7/6
09K
2.3~2.5
in:61~65
out:30~37
in:1~2
out:2~4
Super High
High
Cooling:
Heating:
Summary of Contents for GWC09MA-K3NNA3D
Page 56: ...53 Installation and Maintenance Service Manual GWH09MA K3NNA5F O...
Page 59: ...56 Installation and Maintenance Service Manual...
Page 60: ...57 Installation and Maintenance Service Manual...
Page 61: ...58 Installation and Maintenance Service Manual...
Page 62: ...59 Installation and Maintenance Service Manual...