DC Inverter U-match Series Floor Ceiling Type Unit
39
③
.
The air conditioner circuit should be at least 1.5m away from
any inflammable surface.
④
.
The external power cord, connection wire of indoor and
outdoor units and the communication cords must be effectively
fixed.
⑤
.
The external power cord, connection wire of indoor and
outdoor units and the communication cords can’t directly
contact any hot objects. For example: they must not contact
chimney pipes, warm gas pipes or other hot objects.
⑥
.
The external power cord, communication cords, and the
connection wire of indoor and outdoor units must not be
squeezed. Never pull, stretch or bend the wires.
⑦
.
The external power cord, communication cords and the
connection wire of indoor and outdoor units must not collide
with any metal beam or edge on the ceiling, or touch any metal
burrs or sharp metal edge around.
⑧
.
Connect wires correspondingly by referring to the circuit
diagram labeled on the unit or electric box. Screws must be
tightened up. Slipped screws must be replaced by specialized
flat-head screws.
⑨
.
Please use the power cables that are delivered along with the
air conditioner. Do not change the power cables arbitrarily. Do
not change the length and terminals of the power cables. If you
want to change the power cables, please contact Gree’s local
service center.
⑩
.
Wiring terminals should be connected firmly to the terminal
board. Loose connection is forbidden.
⑪
.
After the electrical installation is finished, please use wire
clamps to secure the power cord, connection wire of indoor