 16

- 30

.

The working range of 

COOL mode and DRY mode

Place requirements:

OPERATING METHODS

- 3-

.

USAGE NOTICE

Unpack the Air Conditioner

Remove packaging materials

Remove and properly dispose the packaging materials. Remove tape and glue residue from surfaces before 

WARNING

Excessive Weight Hazard

Use two or more people to move and install the air conditioner.

Failure to do so can result in back or other injury.

turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. 
Wipe with warm water and dry it.
Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. 
These products can damage the surface of your air conditioner. 

Place the air conditioner on a smooth level floor that strong enough to support the unit.
Allow at least 12 inches (50 cm) of air space on all sides of the unit for good air ventilation.

Place the unit in an area where the temperature will not fall below 16

(61    ). The coils will be covered

with frost at temperatures below 16

(61    ), and this may reduce performance.

NOTE: The portable air conditioner has wheels for easy movement, but it should only be rolled on smooth and 

flat surfaces.Do not attempt to roll the portable air conditioner on carpet or over objects.

12

 (50 cm)

min.

12

 (50 cm)

min.

The appliance is for indoor use only,but shall not be installed in the laundry.

The Max Cooling operation temperature for the air conditioner is 35

.

The appliance shall be installed in accordance with national wiring regulations.

°

F

(86 )

°

F

°

F

°F

°F

Summary of Contents for GPC12AE-A3NNA8A

Page 1: ...ual Portable Air Conditioner Portable Air Conditioner Thank you for choosing Portable Air Conditioner please read this owner s manual carefully before operation and retain it for future reference GPC1...

Page 2: ...DIAGRAM 16 2 WORKING PRINCIPLE 1 3 STRUCTURE 2 4 OPERATING METHODS 3 6 5 7 9 8 CARE AND MAINTENANCE 15 16 10 TROUBLESHOOTING 17 11 USER NOTICES 18 12 AFTER SALES SERVICE 19 13 INSTALLATION AND MAINTE...

Page 3: ...manual is used for reference and the technical parameters are subject to change without notice WORKING PRINCIPLE With the help of upper motor the airflow of indoor pass through the evaporator becomes...

Page 4: ...2 STRUCTURE Front Rear Control panel Air outlet Handle Upper air inlet grille Heat air exhaust vent Power cord Lower air inlet grille...

Page 5: ...can damage the surface of your air conditioner Place the air conditioner on a smooth level floor that strong enough to support the unit Allow at least 12 inches 50 cm of air space on all sides of the...

Page 6: ...ions contact a qualified electrician USAGE NOTICE OPERATING METHODS The wiring must be operated by the professional personnel by circuit Don t connect earth wire to water pipe or gas pipe When the air...

Page 7: ...er of GPC12AE A3NNA8A COOL DRY FAN COOL DRY FAN HEAT COOL GPH12AE A3NNA8A 3 key In COOL or HEAT mode press Names and Functions Remote Controller will increase m o r f d e t c e l e s e b n a c e r u t...

Page 8: ...effect Press MODE key selectthe DRY mode theunitwill runinthe DRY mode at the sametime theuppermotorisrunning at thelowspeed itisnot adjustable COOL mode 1 Press MODE key to select HEAT mode 2 Press...

Page 9: ...b s s e r p n e h W 1 1 y b d e s a e r c n i setting temp will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Swing up and down butt...

Page 10: ...o change timing value quickly then remote controller will send out the signal immediately and hour on off will stop flickering If the time of that no press timer button under flickering status is abov...

Page 11: ...ight in the displayer will be on When the LIGHT is off the icon will be disappeared and all the indicators light in the displayer will be off Light button LIGHT Press this button enter into SLEEP stat...

Page 12: ...nction on or off 5 Press TURBO button to set this function on or off Guide for operation optional operation Introduction for special function This function indicates that moisture on evaporator of ind...

Page 13: ...remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote con...

Page 14: ...ommended to use it with shortest length When installing exhaust pipe should be as flat as possible Don t prolong the pipe or connect it with other exhaust pipe or Correct installation is as shown in f...

Page 15: ...N OF HEAT EXHAUST HOSE following dimension bent too much it would easily cause malfunction 55cm 55cm 13 If the pipe are to be bent please install it by considering Wrong installation is shown in follo...

Page 16: ...14 ACCESSORIES AND INSTALLATION OF HEAT EXHAUST HOSE PARTS INCLUDED Window Exhaust Adapter Rear plastic pipe end Flexible Exhaust Hose Front plastic pipe end...

Page 17: ...n dry it in shade There are wheels at the bottom of the unit according to the demand it can be moved in the Mobile unit Air inlet grille Before maintenance please pull out the power plug and cut off p...

Page 18: ...ature is below 40 104 or the soap water or the water with cleanser after wiping the dirt Do not use gasoline diesel oil or the congeneric substance to clean the unit Before cleaning please pull out th...

Page 19: ...unning in defrosting operation it will resume running in original operation after defrosting Cut off power supply after 10 minutes turn on the unit if still be displays please inform the maintenance m...

Page 20: ...it can cause health problems The unit should be placed about 1m or more away from TV or it will be effected by the electromagnetic wave The air inlet outlet can t be blocked by obstruction or it will...

Page 21: ...r health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposal at least free of charge It is prohibited to dispose o...

Page 22: ...attention to that active carbon can t be cleaned with water Dry it in the shade or sun after cleaning but not by wiping Fig b 3 Put the mounted air inlet grill with filter back Fig a Installation and...

Page 23: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66166066...