background image

1. Remove the continuous drain cap 1 by turning it counter clockwise then remove 

    the rubber stopper 2 from the spout. 

2. Screw the drain connector to(included

     in the package) the spout by turning 

     clockwise. 

   

 

3. Insert the drainage hose into 

    drain connector.

  

 

ATTENTION:

  

  

 

  

 

  

 

Removing Collected Water

When using continuous drainage option from the middle hole, place portable 

on a level surface and make sure garden hose is clear of any obstructions 

and is directed downward. Placing portable on an uneven surface or 

improper hose installation may result in water filling up the chassis and 

causing the unit to shut off. Empty water in  the chassis if shut off occurs, 

then check portable location and hose for proper setup.  

Note:

Water can be automatically emptied into a floor drain by attaching 14mm inner 

diameter hose (not included).

Use the continuous drainage option from the middle hole

 

2

1

2

Summary of Contents for GPA05AK

Page 1: ...Owner s Manual Original Instructions Portable air conditioner Models GPA05AK GPA06AK Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for fu...

Page 2: ...Precaution 16 Preparation before Installation 17 Installation Removing Collected Water 19 Installation in a double hung sash window 22 Installation in a sliding sash window 25 Install Wire Hook 18 Op...

Page 3: ...injury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoide...

Page 4: ...ound the air conditioner should be 12 30cm at least Do not operate the air conditioner at humid environment Please keep air inlet and air outlet clean no obstacles During operation close doors and win...

Page 5: ...mperature can t be lower than 0 Otherwise it will cause water leakage to air conditioner Do not use an extension cord Prohibit operating the unit in the bathroom or laundry room Prohibit inserting any...

Page 6: ...oint B C 5 6 Plug of power cord 7 Filter 8 Air inlet 9 Joint A Remote controller This picture is only for reference Please refer to the actual product for the appearance 1 11 10 9 6 5 7 8 2 3 4 Part s...

Page 7: ...l the air conditioner will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 nixie tube on control panel won t display Under ON status dual 8 n...

Page 8: ...r by pressing or button within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the unit will display temperature if...

Page 9: ...reen 2 1 3 4 5 6 7 1 3 5 2 4 6 7 ON OFF button MODE button button FAN button X FAN button SLEEP button TIMER button Timer on Timer off Sending signal x fan operation sleep operation lock set speed Set...

Page 10: ...arly as below the corresponding icon will be lit up after the mode is selected When selecting cool mode air conditioner will operate under cool mode Then press or button to adjust set temperature Pres...

Page 11: ...nit is off press this button to set Timer On T ON and H icon will be blinking Within 5s press or button to adjust the time for Timer On Pressing or button once will increase or decrease the time by 0...

Page 12: ...n t send signal Note Range of time setting is 0 5 24h The interval between two motions can t exceed 5s otherwise the remote con troller will exit setting status Child lock function Temperature display...

Page 13: ...on remote controller is fuzzy or there s no display please replace batteries 1 After putting through the power press ON OFF button on remote controller to turn on the air conditioner 2 Press MODE butt...

Page 14: ...quency as grease use warm water 104 F 40 C melted with neutral abluent to clean it and then put at shady place to dry it 2 WARNING Before cleaning the air conditioner please turn off the unit and disc...

Page 15: ...1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Ch...

Page 16: ...ether the set temperature is proper Whether door and window are closed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is...

Page 17: ...erature In order to prevent cold air air conditioner will delay for a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting will resume operati...

Page 18: ...ration Water leakage F0 F2 F1 H8 H3 E8 F4 1 Refrigerant is leaking 2 System is blocked 1 Re energize the unit after turning off and pulling out the plug for 30min 2 If there s still malfunction please...

Page 19: ...t of air conditioner The appliance shall not be installed in the laundry 1 Must follow the electric safety regulations when installing the unit 2 3 According to the local safety regulations use qualif...

Page 20: ...st Tools needed for installation cross screwdriver gauge straight screwdriver scissors saw pencil heat discharge pipe window panel sponge B battery AAA 1 5V user s manual remote controller joint B joi...

Page 21: ...Hook Assemble the wire hook at the back of the unit with screws the direction of wire Wind the power cord around the wire hook direction of wire hook is upward direction of wire hook is downward screw...

Page 22: ...hoop drainage port drainage port drainage pipe clip screw Note When using the continuous drainage option from the bottom hole install drainage pipe before using otherwise poor drainage will affect no...

Page 23: ...ed inside the chassis and you do not need to discharge the water frequently 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge wate...

Page 24: ...e hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result...

Page 25: ...clip upper at the rear clip lower fix them together press the clasp forcibly in to the groove adjusting panel window panel cut clasp rear connector lower rear connector upper window panel 2 Clamp joi...

Page 26: ...ow panel to the window stool 7 1 If the inner width of the window is less than 20 5 520mm The window panel cannot be installed in windows less than 20 5 520mm wide 1 Remove the adjustment panel from t...

Page 27: ...ndow is between 37 4 950mm and 56 7 1440mm 8 Cut the sponge B to a proper length and attach it to the window panel inclusive 1 Attach the extension panel to the adjustment panel 2 Open the window sash...

Page 28: ...and outer window sash vertically 11 Fix the inner window with window bracket and screw so that it can not slide sponge A outer window inner window plastic window wooden window window bracket 1 Install...

Page 29: ...ille on joint B C with screws washer and bolt screws washer Bolt Nut Nut Screws Washer Spring washer Rain Shield Spring Washer protective grille 4 Fix the support on the outer side of window panel wit...

Page 30: ...ndow 2 Open the window sash and place the window panel on the window stool 3 Secure the window panel to the window stool with screws 7 2 If the inner width of the window is between 20 5 520mm and 37 4...

Page 31: ...anel inclusive 1 Attach the extension panel to the adjustment panel 2 Open the window sash and place the window panel on the window stool 3 Slide the adjustment and extension panels to fit the window...

Page 32: ...t side of inner window sash and outer window sash 11 Fix the inner window with window bracket and screw so that it can not slide horizontally window sash outer window sponge A inner window plastic win...

Page 33: ...harge pipe 2 Install anather side of heat discharge pipe clockwise into protective grille sub assy 3 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a...

Page 34: ...t discharge pipe should be as flat as possible Don t prolong the pipe or connect it with other heat discharge pipe 31 The discharge pipe is suggested to be installed according to below figure by the m...

Page 35: ...nd lift joint A upwards to remove it Installation and Disassembly of Heat Discharge Pipe 32 Operation Test Put through the power supply and then press ON OFF button on remote contro ller to start the...

Page 36: ...N3 S COMP YEGN C YE CAP K201 AC L COMP AP1 N1 WATER DISP2 RD FAN RD BU SA COM WH HIGH WP RD DISP2 ROOM TEMP DISP1 AP2 M1 BN MOTOR FAN RD CAP SENSOR G AP3 BK NC G YEGN DISP1 COMP MAIN BOARD CAPACITOR Y...

Page 37: ...66129936921...