Multi Variable Air Conditioners Ducted Type Indoor Unit 

20 

8 The Table of Error Codes for Indoor Unit 

Error 

Code 

Content 

Error 

Code 

Content 

Error 

Code 

Content 

L0 

Indoor Unit Error 

L9 

Quantity Of Group Control 

Indoor Units Setting Error 

d8 

Water Temperature 

Error 

L1 

Indoor Fan 

Protection 

LA 

Indoor Units Incompatibility 

Error 

d9 

Jumper Cap Error 

L2 

E-heater Protection 

LH 

Low Air Quality Warning 

dA 

Indoor Unit Network 

Address Error 

L3 

Water Full 

Protection 

LC 

ODU-IDU Incompatibility 

Error 

dH 

Wired Controller PCB 

Error 

L4 

Wired Controller 

Power Supply Error 

d1 

Indoor Unit PCB Error 

dC 

Capacity DIP Switch 

Setting Error. 

L5 

Freeze protection 

d3 

Ambient Temperature 

Sensor Error 

dL 

Outlet Air Temperature 

Sensor Error 

L7 

No Master Indoor 

Unit Error 

d4 

Inlet Pipe Temperature 

Sensor Error 

dE 

Indoor Unit CO

2

 Sensor 

Error 

L8 

Power Insufficiency 

Protection 

d6 

Outlet Pipe Temperature 

Sensor Error 

C0 

Communication Error 

L0 

Indoor Unit Error 

d7 

Humidity Sensor Error 

AJ 

Filter Cleaning Reminder 

o1 

Low bus bar voltage 

of indoor unit   

o2 

High bus bar voltage of 

indoor unit 

o3 

IPM Module Protection 

of Indoor Unit   

o4 

Failure Startup of 

Indoor Unit   

o5 

Overcurrent Protection of 

Indoor Unit   

o6 

Current Detection Circuit 

Malfunction of Indoor 

Unit   

o7 

Desynchronizing 

Protection of Indoor 

Unit   

o8 

Communication Malfunction 

of Indoor Unit’s Drive   

o9 

Communication 

Malfunction of Main 

Mater of Indoor Unit 

oA 

High temperature of 

Indoor Unit’s 

Module 

ob 

Malfunction of Temperature 

Sensor of Indoor Unit’s 

Module   

oC 

Charging Circuit 

Malfunction of Indoor 

Unit   

o0 

Other Drive 
Malfunction 

db 

Special Code: Field Debugging Code 

 
 

 

Summary of Contents for GMV-ND30PLS/C-T

Page 1: ...Owner s Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Ducted Type Indoor Unit Models GMV ND30PLS C T U GMV ND36PLS C T U GMV ND42PLS C T U GMV ND48PLS C T U...

Page 2: ...perate normally please contact our service center as soon as possible and provide the following information 1 Content on the nameplate model number cooling capacity production codex factory date 2 Mal...

Page 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Page 4: ...4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 14 5 Wiring Work 14 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Connection of Communication...

Page 5: ...rmally 13 When installation is finished please check whether the drainage pipes pipelines and electric wires are connected correctly to avoid water leakage refrigerant leakage electric shock or fire e...

Page 6: ...Bulb Temp C F Wet Bulb Temp C F Rated Cooling 26 7 80 0 19 4 67 0 35 95 0 23 9 75 0 Rated Heating 21 1 70 0 15 6 60 0 8 3 47 0 6 1 43 0 3 Preparations for Installation Product graphics are only for r...

Page 7: ...on for Installation 1 The appliance shall not be installed in the laundry 2 The top holder must be strong enough to support unit s weight 3 Drain pipe can drain water out easily 4 There is no obstacle...

Page 8: ...ed twisted pair communication cable must be adopted 3 3 1 Select Communication Line for Indoor Unit and Wired Controller Fig 3 3 1 Material type Total length of communication line between indoor unit...

Page 9: ...GMV ND36PLS C T U 3 0 15 GMV ND42PLS C T U 3 0 15 GMV ND48PLS C T U 3 0 15 1 Use copper wire only as unit s power cord Operating temperature should be within its rated value 2 If the power cord is mor...

Page 10: ...ND30PLS C T U GMV ND48PLS C T U Fig 4 1 1 Below are dimensions of A B C etc for different models Unit mm inch Model A B C D E F G H I GMV ND30PLS C T U 1379 54 5 16 565 22 1 4 1340 52 3 4 655 25 13 1...

Page 11: ...lt Be sure to fix it securely by using a nut and washer from upper and lower sides of the hanger bracket The washer fixing plate will prevent the washer from falling Unit mm inch Fig 4 1 5 Before oper...

Page 12: ...n tighten the flaring nut with hand as shown in Fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 Torque for tightening nut Pipe diameter mm inch Torque N m 6 35 1 4 15 30 9 52 3 8 35 4...

Page 13: ...lead to water leakage and damp the furniture and other things in the room 7 You can buy normal hard PVC pipe used as the drainage pipe During connection insert the end of PVC pipe into the drainage ho...

Page 14: ...apacity Unit mm inch Fig 4 3 4 5 Install the trap as shown in following Fig 4 3 5 Fig 4 3 5 6 Install one trap for each unit 7 Convenience for cleaning trap in the future should be considered when ins...

Page 15: ...4 3 10 4 3 3 Test of Drainage System 1 Please test drainage system after electric work is finished Inject approximately 1L purified water to drain pan from air vent ensure that not to splash the wate...

Page 16: ...air return duct should be fixed on a pre made board with iron frame The junction of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should compl...

Page 17: ...nd the return air cover plate is at the bottom as shown in Fig 4 4 5 Fig 4 4 5 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover plate 3 Co...

Page 18: ...before operation Please refer to Instruction Manual of ODU for auto addressing and debugging details 5 Wiring Work Before obtaining access to terminals all supply circuits must be disconnected 1 Unit...

Page 19: ...l of wire into ring by needle nose plier and keep the gauge of ring in accordance with screw 4 Use the screwdriver for tightening the terminal 2 The connection of stranded wire as shown in Fig 5 1 2 1...

Page 20: ...2 1 1 Detach the electric box lid 2 Let the power cord pass through the wiring through holes 3 Connect wires according to Fig 5 2 1 4 Fix the power cord with wiring clamp 5 The wire diameter of power...

Page 21: ...ht board and wired controller See Fig 5 4 1 for the installation of wired controller Fig 5 4 1 5 5 Illuminate for Connection of Wired Controller and Indoor Units Network 1 Communication wire of indoor...

Page 22: ...ic pressure to the respective static pressure notch please see as below The setting of static pressure for indoor fan can be done via wired controller For specific setting method please see the Wired...

Page 23: ...Use a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent and dry the filters in the shade 2 If the unit used in the environment with much dust please...

Page 24: ...Sensor Error L7 No Master Indoor Unit Error d4 Inlet Pipe Temperature Sensor Error dE Indoor Unit CO2 Sensor Error L8 Power Insufficiency Protection d6 Outlet Pipe Temperature Sensor Error C0 Communic...

Page 25: ...ilter is dirty Too heavy heat load of room e g too many people Door or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high Refrigerant is insufficient e g refrigerant l...

Page 26: ......

Reviews: