Multi Variable Air Conditioners Duct Type Indoor Unit

 

1 Safety Precautions   

  means items that must be forbidden! Otherwise, it may lead to personal injury or death or 

serious damage.   

  means items that must be followed! Otherwise, it may lead to personal injury or property loss. 

 

Please install the unit accordingto 

instructions in this manual. Read 

this manual carefully before 

starting up or checking the 

machine. 

 

Installation should be 

performed by dealer or 

qualified technicians. Do 

not install the product by 

yourself. Improper 

installation may result in 

water leakage, electric 

shock or fire hazard. 

 

Make sure the local power supply 

is in accordance with units before 

installation, and check the power 

supply carefully. 

 

This air conditioner must be 

properly grounded through 

the receptacle to avoid 

electric shock.The 

grounding wire    shouldn't 

be connected with gas pipe, 

water pipe, lightning 

arrester or telephone line. 

 

Please use specialized 

accessories or parts to carry out 

installation,or water leakage, 

electric shock,fire hazard may 

resulted. 

 

R410A refrigerant can 

produce poisonous gas 

once it meets fire, so please 

ventilate the room 

immediately if refrigerant 

leaks out during installation. 

 

Diameter of power cord must be 

large enough. Damaged power 

cord and connecting wire must be 

replaced by specialized electric 

cable. 

 

After the power cord is 

connected, please install 

the cover of electric box to 

avoid danger. 

 

Nitrogen must be charged   

according to technical 

requirements. 

 

Short circuit is forbidden. 

Do not cancel the pressure 

switch in case the unit may 

be damaged. 

Summary of Contents for GMV-ND22PLS/A-T

Page 1: ...Air Conditioners please read this owner s manual carefully before operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visit www gree com...

Page 2: ...ensuring reliability of complete unit maintaining normal communication and preheating refrigerant When the unit won t be used for a long time cut off the power of the complete unit However please pre...

Page 3: ...n and Drainage System Testing 12 4 4 Installation of Air Duct 15 4 5 Installation of Wired Controller 18 5 Wiring Work 19 5 1 Connection of Wire and Patch Board Terminal 19 5 2 Power Cord Cnnection 20...

Page 4: ...eck the power supply carefully This air conditioner must be properly grounded through the receptacle to avoid electric shock The grounding wire shouldn t be connected with gas pipe water pipe lightnin...

Page 5: ...lack of oxygen Never start or stop the air conditioner by inserting or removing the power cord Do not turn off the air conditioner until it runs for at least 5 minutes Otherwise oil return of the com...

Page 6: ...off the unit at once and disconnect power supply Then contact GREE service center If the air conditioner continues to operate despite of abnormal condition the unit may be damaged and it may cause ele...

Page 7: ...ating 20 15 7 6 Indoor Unit Working Temperature Range 16 C 32 C 2 3 Unit Functions Unit Functions Wired Controller XK46 Standard Wired Controller XK49 Optional Remote Controller YAP1F Standard Remote...

Page 8: ...trol the indoor unit 2 M4X25 Screw Cross recessed small pan head screw 3 To fix the wired controller 3 Drain Hose Assembly 1 To connect with the hard PVC drain pipe 4 Special Nut 1 To be used for conn...

Page 9: ...rwise these electrical appliances may have image interference and noise Even if the distance is 1m when there is strong electric wave noise may still occur Fig 3 2 Notes Installation of the unit must...

Page 10: ...is installed in places with intense magnetic field or strong interference it is necessary to use shielded wire 3 3 2 Select communication line for indoor unit and outdoor unit Fig 3 3 2 Wire Type Tota...

Page 11: ...T 6 1 0 1 0 Notes Use copper wire only as unit s power cord Operating temperature should be within its rated value If the power cord is more than 15m long please increase properly the sectional area o...

Page 12: ...tric box and below unit s lower level 1 Below are the outline dimension applicable to indoor units of GMV ND22PLS A T GMV ND63PLS A T Fig 4 4 1 Below are dimensions of A B C etc for different models U...

Page 13: ...260 222 1016 220 1050 695 GMV ND80PLS A T GMV ND90PLS A T 1379 565 1340 655 260 207 1153 220 1188 716 GMV ND100PLS A T GMV ND112PLS A T GMV ND125PLS A T GMV ND140PLS A T 1 Drill bolt holes and install...

Page 14: ...nger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension The center of ceiling openin...

Page 15: ...rainage pipe should be short and the gradient downwards should be at least 1 2 in order to drain condensation water smoothly 2 The diameter of drainage hose should be bigger or equal to the diameter o...

Page 16: ...lamp with the distance between screw nut and hose smaller than 4mm metal clamp accessory drain hose accessory Fig 4 3 2 Fig 4 3 3 3 Use sealing plate to make the pipe clamp and hose insulated as shown...

Page 17: ...ds drainage direction should be at least 1 2 If the raising pipe is vertical with the unit the raising height should be less than 800mm Fig 4 3 9 10 Drain pipes should have a downward slope of at leas...

Page 18: ...n order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of air return duct is suggested to be more than 150mm away from the wall Add a...

Page 19: ...utlet and Air return Opening 1 Range of Capacity 2 2 6 3kW Fig 4 4 3 Air Outlet Fig 4 4 4 Air return Opening Model Size of Air Outlet Size of Air return Opening A B C D GMV ND22PLS A T 121 528 580 161...

Page 20: ...return air is desired just change the place of the rectangular flange and the return air cover plate 3 Connect one end of the return air duct to the return air outlet of the unit by rivets and the ot...

Page 21: ...f the fresh air duct is not be used 2 Install the round flange so that the fresh air duct can be connected as Fig 4 4 10 3 Sealing and heat preservation should be done for both the air pipe and round...

Page 22: ...e communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1 Co...

Page 23: ...wiring clamp 5 3 Connection of Communication Wire between Indoor Unit and Outdoor Unit or indoor unit 1 Detach the electric box lid 2 Let the Communication cable pass through the wiring through holes...

Page 24: ...remote controller 3 Wired controller and receiving light board can be installed at the same time When operating through a remote controller both wired controller and the receiving light board can rec...

Page 25: ...e 2 If the unit used in the environment with much dust please clean it regularly usually once every two weeks 6 2 Maintenance before the Seasonal Use 1 Check if the air inlet and air outlet of indoor...

Page 26: ...ty Input voltage is too low Defect of main PC board The unit stops after running for a while The inlet or outlet of ODU or IDU are blocked by obstacle Poor cooling effect The filter is dirty Too heavy...

Page 27: ...Multi Variable Air Conditioners Duct Type Indoor Unit 24...

Page 28: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...